A deep neural network for 12-lead electrocardiogram interpretation outperforms a conventional algorithm, and its physician overread, in the diagnosis of atrial fibrillation.
Clicks: 439
ID: 44843
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
73.0
/100
439 views
286 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #2 of 9 articles by views in international journal of cardiology heart & vasculature
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
10
SUSD
one-off · no wallet required
Abstract
Automated electrocardiogram (ECG) interpretations may be erroneous, and lead to erroneous overreads, including for atrial fibrillation (AF). We compared the accuracy of the first version of a new deep neural network 12-Lead ECG algorithm (Cardiologs®) to the conventional Veritas algorithm in interpretation of AF.24,123 consecutive 12-lead ECGs recorded over 6 months were interpreted by 1) the Veritas® algorithm, 2) physicians who overread Veritas® (Veritas® + physician), and 3) Cardiologs® algorithm. We randomly selected 500 out of 858 ECGs with a diagnosis of AF according to either algorithm, then compared the algorithms' interpretations, and Veritas® + physician, with expert interpretation. To assess sensitivity for AF, we analyzed a separate database of 1473 randomly selected ECGs interpreted by both algorithms and by blinded experts.Among the 500 ECGs selected, 399 had a final classification of AF; 101 (20.2%) had ≥1 false positive automated interpretation. Accuracy of Cardiologs® (91.2%; CI: 82.4-94.4) was higher than Veritas® (80.2%; CI: 76.5-83.5) ( < 0.0001), and equal to Veritas® + physician (90.0%, CI:87.1-92.3) ( = 0.12). When Veritas® was incorrect, accuracy of Veritas® + physician was only 62% (CI 52-71); among those ECGs, Cardiologs® accuracy was 90% (CI: 82-94; < 0.0001). The second database had 39 AF cases; sensitivity was 92% vs. 87% ( = 0.46) and specificity was 99.5% vs. 98.7% ( = 0.03) for Cardiologs® and Veritas® respectively.Cardiologs® 12-lead ECG algorithm improves the interpretation of atrial fibrillation.
| Reference Key |
smith2019ainternational
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Smith, Stephen W;Rapin, Jeremy;Li, Jia;Fleureau, Yann;Fennell, William;Walsh, Brooks M;Rosier, Arnaud;Fiorina, Laurent;Gardella, Christophe; |
| Journal | international journal of cardiology heart & vasculature |
| Year | 2019 |
| DOI |
10.1016/j.ijcha.2019.100423
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.