Ultrasound assisted extraction of lycopene from tomato processing wastes.

Clicks: 358
ID: 44714
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Star

Ranked #18 of 110 articles by views in Journal of food science and technology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Tomato paste processing wastes, an important by-product of the paste industry, is rich in potentially health-promoting compounds such as lycopene. In this study, extraction yield of lycopene from tomato paste processing wastes by application of ultrasound assisted extraction (UAE) was compared with conventional organic solvent extraction (COSE) method. BHT (butylated hydroxytoluene) 0.05 % (w/v) added hexane:acetone:ethanol (2:1:1) mixture was used as solvent. Three different solvent solid ratios; 50:1, 35:1 and 20:1, (v/w) were used in both COSE and UAE. COSE experiments were performed at 20 °C, 40 °C and 60 °C for 10, 20, 30 and 40 min. 50, 65 and 90 W of ultrasonic power were applied in UAE for 1, 2, 5, 10, 15, 20 and 30 min. Lycopene contents of the samples were determined by spectrophotometric method. The effects of different factors, including the temperature, solvent solid ratio and ultrasonic power on lycopene yield were investigated. It was determined that the most efficient application for COSE was extracting samples by 50:1 solvent solid ratio at 60 °C for 40 min run, for UAE, 35:1 (v/w) solvent solid ratio, 90 W ultrasonic power for 30 min run. It was showed that UAE of lycopene requires less time, lower temperature and lower solvent than COSE.
Reference Key
kumcuoglu2014ultrasoundjournal Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Kumcuoglu, Seher;Yilmaz, Tuncay;Tavman, Sebnem;
Journal Journal of food science and technology
Year 2014
DOI
10.1007/s13197-013-0926-x
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.