Spectrophotometric method development and validation for determination of chlorpheniramine maleate in bulk and controlled release tablets.

Clicks: 205
ID: 39418
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #30 of 39 articles by views in pakistan journal of pharmaceutical sciences

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Spectrophotometric technique is considered to be the simplest and operator friendly among other available analytical methods for pharmaceutical analysis. The objective of the study was to develop a precise, accurate and rapid UV-spectrophotometric method for the estimation of chlorpheniramine maleate (CPM) in pure and solid pharmaceutical formulation. Drug absorption was measured in various solvent systems including 0.1N HCl (pH 1.2), acetate buffer (pH 4.5), phosphate buffer (pH 6.8) and distil water (pH 7.0). Method validation was performed as per official guidelines of ICH, 2005. High drug absorption was observed in 0.1N HCl medium with λ of 261nm. The drug showed the good linearity from 20 to 60μg/mL solution concentration with the correlation coefficient linear regression equation Y= 0.1853 X + 0.1098 presenting R value of 0.9998. The method accuracy was evaluated by the percent drug recovery, presents more than 99% drug recovery at three different levels assessed. The % RSD value <1 was computed for inter and intraday analysis indicating the high accuracy and precision of the developed technique. The developed method is robust because it shows no any significant variation in with minute changes. The LOD and LOQ values were assessed to be 2.2μg/mL and 6.6μg/mL respectively. The investigated method proved its sensitivity, precision and accuracy hence could be successfully used to estimate the CPM content in bulk and pharmaceutical matrix tablets.
Reference Key
ashfaq2018spectrophotometricpakistan Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Ashfaq, Maria;Sial, Ali Akber;Bushra, Rabia;Rehman, Atta-Ur;Baig, Mirza Tasawur;Huma, Ambreen;Ahmed, Maryam;
Journal pakistan journal of pharmaceutical sciences
Year 2018
DOI
DOI not found
URL URL not found
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.