Cardiorespiratory Physiology following Minimally Invasive Surfactant Therapy in Preterm Infants.
Clicks: 373
ID: 38582
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
76.7
/100
373 views
270 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #4 of 28 articles by views in neonatology
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Surfactant replacement therapy through the endotracheal tube has been shown to improve lung compliance and reduce pulmonary pressures. Minimally invasive surfactant therapy (MIST) combines the benefits of continuous positive airway pressure (CPAP) and surfactant for spontaneously breathing preterm infants. We aimed to characterize the haemodynamic changes accompanying the first dose of MIST in preterm infants.Poractant alfa (200 mg/kg) was administered as MIST while on CPAP support. Echocardiograms were performed before (T1) and 30 (T2) and 60 min (T3) after MIST to assess serial change.Twenty infants (mean gestational age 29.5 ± 2.8 weeks, median birth weight 1,102 g, IQR 840-1,940) received MIST at a median age of 16 h (IQR 3-24). FiO2 decreased significantly at 30 min (0.41 ± 0.08 to 0.27 ± 0.03, p < 0.001). Significant changes were noted at T2 for ductal parameters (decreased % time right to left shunt: 25% [15-33] to 14.5% [6-22], p = 0.013). Reduced pulmonary vascular resistance (PVR; increased pulmonary artery time velocity ratio 0.23 ± 0.05 to 0.28 ± 0.04 ms, p = 0.004) and improved longitudinal (tricuspid annular plane systolic excursion 4.5 ± 0.8 to 5.3 ± 0.9 mm, p = 0.004) and global (fractional area change 25 ± 2.3 vs. 27 ± 2%, p = 0.002) ventricular function were noted.This is the first study assessing cardiovascular adaptation to MIST, a procedure fast gaining acceptance in the neonatal community. Increased pulmonary blood flow is likely due to a combined effect of increased ductal flow, reduced PVR, and increased ventricular function.
| Reference Key |
sehgal2019cardiorespiratoryneonatology
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Sehgal, Arvind;Bhatia, Risha;Roberts, Calum T; |
| Journal | neonatology |
| Year | 2019 |
| DOI |
10.1159/000502040
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.