Identification of new interferences leached from plastic microcentrifuge tubes in electrospray ionization mass spectrometry.

Clicks: 411
ID: 3600
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #2 of 106 articles by views in Rapid communications in mass spectrometry : RCM

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The incredible sensitivity of the modern mass spectrometry instrument enables scientists to detect a large number of molecules ranging from small organic compounds to biological macromolecules. However, the same sensitivity often throws up challenges with respect to background interferences and contaminants. The identification and source of these contaminants is very important for reducing background contamination and ensuring the accuracy of the analysis results.The interfering compounds were analyzed by high-performance liquid chromatography coupled with a hybrid quadrupole-orbitrap mass spectrometer. The structural analysis was conducted by obtaining the accurate masses of precursors and their fragment ions. The retention time and MS/MS spectrum of one of the interfering compounds (N-lauryldiethanolamine) were compared with an authentic standard to reach an unequivocal structural assignment.The interferences (m/z 274 and 318 in positive mode) were observed during the analysis of herbicides in tea samples by electrospray ionization mass spectrometry (ESI-MS). Their structures were identified to be N-lauryldiethanolamine and N-(2-hydroxyethyl)-N-(2-(2-hydroxyethoxy)ethyl)dodecylamine by fragmentation interpretation and further confirmed by a standard compound. These interferences were found to be leached from the plastic microcentrifuge tubes used during sample pretreatment. The plastic tubes from two of the five suppliers tested were found to contain these two interferences.In this work, we presented an example about the observation, identification and source of interferences in ESI-MS. The N-lauryldiethanolamine and other ethoxylated aliphatic alkylamines are common plastic antistatic agents. They possess high proton affinity so that they show a strong response in ESI positive mode. In order to avoid their interference during mass spectrometric analysis we need to choose plastic tubes (or other plastic materials) that do not contain such antistatic agents.
Reference Key
chai2019identificationrapid Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Chai, Yunfeng;Chen, Hongping;Gao, Guanwei;Liu, Xin;Lu, Chengyin;
Journal Rapid communications in mass spectrometry : RCM
Year 2019
DOI
10.1002/rcm.8431
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.