A Comparison of Thermal Changes among Four Different Interproximal Reduction Systems in Orthodontics.

Clicks: 241
ID: 35770
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #7 of 12 articles by views in The journal of contemporary dental practice

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Interproximal enamel stripping is routinely used in orthodontics, different methods were utilized by clinicians to reduce the width of teeth but no previous study addressed the factors affecting the thermal safety of such systems on the dental pulp.The present study was conducted to measure thermal changes among four different interproximal reduction (IPR) systems in orthodontics.A total of 130 extracted human premolar teeth were used in this study. Teeth were distributed into three experimental groups each having three subgroups and one control group. Thus, a total of 10 subgroups were created of 13 teeth each. Stripping procedures were performed using four diamond tools (burs, discs, saw, and manual strip) with different speed setup, with and without a coolant for the higher speed setup for each tool. A K-type thermocouple wire was positioned in the center of the pulp chamber and was connected to a data logger during the application of stripping procedures. Data were analyzed by the Krushkal-Wallis test using the SPSS PC+ version 21.0 statistical software.There was a highly statistically significant difference in the mean ranks of temperature values among the four groups with different speed levels. Among the 10 subgroups, the higher change in temperature registered was in the bur and disc groups when operated with the highest recommended speed without a coolant. The change in temperature was statistically significantly higher than the temperature values of other groups (p < 0.001). All recorded temperatures were below the critical temperature (5.5 °C) registered.Based on the results of this study, IPR is a safe procedure on the dental pulp for the teeth with a medium dentin thickness with or without a coolant.
Reference Key
omer2019athe Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Omer, Amina Balla Al-Hassan;Sanea, Jamal Al;
Journal The journal of contemporary dental practice
Year 2019
DOI
DOI not found
URL URL not found
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.