Development of a LC-MS method for the determination of synthetic cathinones in urine samples based on switchable hydrophilicity solvent extraction

Clicks: 4
ID: 340985
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #72 of 72 articles by views in journal of analytical toxicology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The continuous emergence of synthetic cathinones as new psychoactive substances (NPS) poses significant challenges for analytical toxicology, demanding efficient, reliable, and environmentally sustainable approaches for their determination in biological matrices. In this study, a homogeneous liquid–liquid microextraction method based on a switchable hydrophilicity solvent (SHS-HLLME) was developed and optimized for the determination of synthetic cathinones in urine, followed by liquid chromatography–mass spectrometry analysis. A multivariate experimental design was applied to optimize key extraction parameters, enabling efficient analyte recovery while minimizing organic solvent consumption. The optimized conditions consisted of 500 µL of urine, 400 µL of SHS:HCl mixture, and 400 µL of NaOH. The method was validated, showing satisfactory linearity (R² > 0.99), limits of detection and quantification of 10 ng/mL and 20 ng/mL, respectively, as well as acceptable recovery and precision across the evaluated concentration range. Matrix effects were low (≤10.1%), indicating negligible interference from endogenous components. Compared to conventional extraction approaches, the proposed method offers a simplified workflow with reduced solvent consumption, in line with the principles of Green Analytical Toxicology. Overall, the method was simple and cost-effective, demonstrating its suitability for routine determination of synthetic cathinones in urine and its potential as an environmentally friendly alternative for forensic and clinical toxicology applications.
Reference Key
openalex_W7236713335 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal journal of analytical toxicology
Year 2026
DOI
10.1093/jat/bkag101
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.