Novel zwitterionic HILIC stationary phase for the determination of ethyl glucuronide in human hair by LC-MS/MS.
Clicks: 222
ID: 34095
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
63.1
/100
222 views
179 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #27 of 46 articles by views in journal of chromatography b, analytical technologies in the biomedical and life sciences
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Some recent studies have described a shift from traditional reversed-phase to more hydrophilic LC chemistry for EtG determination in hair (hEtG). The reason relies on the poor retention of C8- and C18-based columns for polar compounds, even in presence of great amount of aqueous phase. This work presents the development, validation and application of a new hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-LC-MS/MS) method based on a novel zwitterionic stationary phase for the analysis of hEtG. The linearity was assessed in the range of 5-100 pg/mg hair, with a correlation coefficient of >0.99. The method was selective and sensitive, with a limit of detection (LOD) and limit of quantitation (LOQ) of 1.4 pg/mg and 4.5 pg/mg in hair, respectively. Suitable diagnostic sensitivity was achieved without the introduction of a sample purification step, or a post column solvent addition. The method was successfully applied to real hair samples after full validation. This method, based on a separation at neutral conditions, confirmed the optimum retention and thus selectivity for weak acids in zwitterionic HILIC columns.
| Reference Key |
palumbo2018noveljournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Palumbo, Diego;Fais, Paolo;Calì, Anna;Lusardi, Monica;Bertol, Elisabetta;Pascali, Jennifer P; |
| Journal | journal of chromatography b, analytical technologies in the biomedical and life sciences |
| Year | 2018 |
| DOI |
S1570-0232(18)30840-7
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.