Venous Vascular Closure System Versus Conventional Figure of Eight Suture Following Single Shot Device Pulmonary Vein Isolation: The VASC-AF Study

Clicks: 13
ID: 340663
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #150 of 150 articles by views in EP Europace

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 150 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
AIMS: Optimization of femoral venous access management has become increasingly important as catheter ablation of atrial fibrillation (AF) continues to evolve towards greater safety with accelerated recovery pathways. We evaluated the efficacy and safety of a bioabsorbable venous vascular closure system (VCS) compared with a conventional figure-of-eight (F8) suture and manual compression following contemporary single-shot pulmonary vein isolation (PVI). METHODS AND RESULTS: VASC-AF was a prospective, multicentre, randomized controlled trial performed at three German electrophysiology centres. One hundred consecutive patients undergoing single-shot PVI were randomized in a 1:1 ratio to femoral venous closure using the VASCADE MVP VCS; (n=50) or conventional F8 suture (n=50). The primary efficacy endpoint was time to ambulation. The primary safety endpoint comprised major periprocedural adverse events requiring medical intervention before hospital discharge.Baseline characteristics and procedural variables were comparable between study groups. Median time to ambulation was significantly shorter following vascular closure with VCS compared with F8 sutures (120 [120-150] vs. 180 [180-240] min; P=0.015). Likewise, time to haemostasis (0.5 [0.5-2] vs. 1 [1-2] min; P=0.021) and time to discharge eligibility (2.5 [2.1-3.0] vs. 4.0 [3.0-5.0] h; P=0.019) were significantly reduced.Major adverse events occurred infrequently and did not differ significantly between groups. In contrast, vascular closure using VCS significantly reduced minor vascular access complications (6% vs. 26%; P=0.006), groin pain, and patient discomfort while improving overall post-procedural satisfaction. CONCLUSION: Among patients undergoing contemporary single-shot AF ablation, use of a bioabsorbable VCS significantly accelerated post-procedural recovery while maintaining a comparable major safety profile. Reduced access-site complications and improved patient-reported outcomes support VCS as an important component of enhanced recovery pathways following AF ablation especially in an ambulatory or Same-Day Discharge setting.
Reference Key
openalex_W7235870274 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal EP Europace
Year 2026
DOI
10.1093/europace/euag329
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.