Reducing inappropriate pneumatic tube transport of restricted medications through an EHR-integrated safeguard

Clicks: 13
ID: 340517
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #261 of 279 articles by views in American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 279 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Purpose Pneumatic tube systems (PTS) improve medication delivery efficiency in hospitals but are inappropriate for certain medications due to risks involving product integrity, hazardous drug exposure, diversion, or medication loss. Despite institutional do-not-tube policies, inappropriate transport events continue to occur. This study evaluated the impact of an electronic health record (EHR)–integrated safeguard designed to reduce inappropriate pneumatic tube transport of restricted medications in a pediatric oncology hospital. Summary This retrospective quality improvement study was conducted at a 73-bed pediatric oncology institution using an institution-wide PTS. Dispense tracking data were evaluated before (July to December 2024) and after (July to December 2025) intervention. Before intervention, all medication delivery methods, including tube delivery, were available for technician selection in EHR dispense tracking, regardless of medication restrictions. Following an EHR upgrade, a rule-based safeguard removed the pneumatic tube delivery option for medications identified as inappropriate for tube delivery on the basis of medication administration instructions and medication naming conventions. A total of 124,379 dispenses were evaluated before the intervention and 113,107 were evaluated after the intervention. The number of inappropriate tube transport events decreased from 370 to 61 following intervention. The rate of inappropriate transport declined from 2.97 to 0.54 events per 1,000 dispenses, corresponding to an 82% relative reduction (incidence rate ratio, 0.18; 95% confidence interval, 0.13-0.22; P < 0.0001). Conclusion Embedding an operational safeguard directly within EHR dispense tracking workflows substantially reduced inappropriate pneumatic tube transport of restricted medications without introducing additional interruptive alerts. This systems-based intervention represents a scalable, low-maintenance strategy to improve medication handling safety and reinforce institutional transport policies.
Reference Key
openalex_W7236118848 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists
Year 2026
DOI
10.1093/ajhp/zxag403
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.