Predicting culture positivity rates for Shiga toxin-producing Escherichia coli and Shigella species based on real time PCR cycle threshold values

Clicks: 10
ID: 339822
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #242 of 245 articles by views in FEMS microbiology letters

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 245 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
PCR assays for the detection of Shiga toxin-producing Escherichia coli (STEC) and Shigella species/Enteroinvasive E. coli (EIEC) provide a robust, specific and sensitive diagnostic test. Real time PCR cycle threshold (ct) values provide an indication of bacterial load within a faecal specimen. We reviewed real time PCR ct values to determine whether there was a cut off after which obtaining a positive culture would be unlikely, enabling resources to be focused on specimens most likely to be culture positive. There were 685 faecal specimens included in the study, divided into three groups with ct values < 30 (n = 251), 30-35 (n = 352) and > 35 (n = 82). Of these, 330/685 (48.2%) were culture positive for either STEC (n = 316) and/or Shigella/EIEC (n = 14). The highest proportion of PCR-culture positive specimens had ct values < 30 (<30 n = 175/251, 69.7%; 30-35 n = 137/352, 38.9%; >35 n = 18/82, 22.0%). Culture was three times more likely to be successful in specimens where the ct value was < 30 compared to > 35. However, in some instances culture was achieved where the ct was > 35. Although ct values can be used to predict successful culture, specimens testing positive for STEC by real time PCR from vulnerable patients and those reporting clinically severe symptoms, should be referred to the reference laboratory regardless of the ct value.
Reference Key
openalex_W7226018173 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal FEMS microbiology letters
Year 2026
DOI
10.1093/femsle/fnag140
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.