Rapid genotyping of Salmonella using Oxford Nanopore-only sequencing for outbreak investigation

Clicks: 13
ID: 339459
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #224 of 230 articles by views in Journal of applied microbiology

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 230 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Aims Whole genome sequencing of Salmonella is a powerful tool for case identification during outbreak investigations. Long-read sequencing with Oxford Nanopore is a promising option due to its speed and cost-effectiveness, albeit with the downside of potential higher error rates. However, recent technological developments have greatly increased its accuracy. In this study, we tested the performance of Oxford Nanopore-only sequencing for core genome multilocus sequence typing (cgMLST) of Salmonella during outbreak investigations. Methods and Results We sequenced 40 Salmonella isolates from six different serovars from historical outbreak-associated and sporadic cases from Norway with Illumina and Oxford Nanopore technologies. We tested different basecalling, filtering, assemblers and polishing tools, and calculated allelic differences (ad) between Illumina and Oxford Nanopore assemblies. cgMLST typing of the Oxford Nanopore-only assemblies agreed with the Illumina references: all outbreak samples clustered appropriately, with an average ad of 0.10 between the two technologies. Basecalling and polishing steps had the greatest impact on Oxford Nanopore genotyping accuracy. We found accurate genotyping could be obtained in as early as five hours of sequencing, leading to a colony-to-result turnaround time of around 24 hours. However, accurate antimicrobial gene detection and plasmid reconstruction remained challenging. Conclusions As of R10.4.1 flowcells and v.4.3.0 basecalling models, Nanopore-only sequencing is a viable and rapid alternative to Illumina for Salmonella genotyping during outbreak investigations, offering comparable results in a faster turnaround time.
Reference Key
openalex_W7225698747 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal Journal of applied microbiology
Year 2026
DOI
10.1093/jambio/lxag275
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.