Development of an HPLC–UV–Vis Method for the Determination of Epirubicin Residues on Stainless-Steel Surfaces

Clicks: 10
ID: 337515
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #375 of 376 articles by views in journal of aoac international

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 376 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background Cross-contamination control is essential in pharmaceutical manufacturing for highly potent and cytotoxic active pharmaceutical ingredients used in oncology products. Epirubicin, an anthracycline antineoplastic agent, requires reliable residue monitoring after cleaning because residual carryover on shared manufacturing equipment may pose quality and safety risks. Objective This study aimed to develop a practical HPLC–UV–Vis method for epirubicin determination, evaluate its chromatographic performance using solution-based standards and quality-control samples, and apply the method to swab samples collected from contaminated stainless-steel surfaces following different cleaning procedures. Methods Chromatographic separation was achieved on a Poroshell 120 SB-C8 column using an isocratic mobile phase of acetonitrile and purified water containing 0.1% orthophosphoric acid (28:72, v/v) at 0.5 mL/min, with UV–Vis detection at 480 nm, within the visible region. Chromatographic performance was evaluated using solution-based standards and quality-control samples for selectivity, carryover, linearity, sensitivity, accuracy, precision, stability, and system suitability. AISI 304 matte stainless-steel plates were contaminated with epirubicin solution, subjected to different cleaning procedures, and sampled by swabbing. Surface recovery was assessed separately at a single spiking level. Results The method was linear over 20–1000 ng/mL. The LOQ was established at 20 ng/mL (S/N = 10.2). The single-level surface-recovery assessment yielded a recovery of 70.5%. Cleaning procedures including 2% sodium hydroxide resulted in no quantifiable parent epirubicin peak under the applied chromatographic conditions. Conclusion The developed HPLC–UV–Vis method showed suitable chromatographic performance for epirubicin determination under the investigated solution-based conditions and was applied to residue monitoring in swab samples collected from stainless-steel surfaces following cleaning. Because surface recovery was assessed at only one spiking level, the complete surface-sampling and extraction procedure was not comprehensively validated. Highlights The developed HPLC–UV–Vis method was applied to epirubicin residue monitoring in swab samples collected from stainless-steel surfaces, with no quantifiable parent epirubicin peak observed after sodium hydroxide-containing cleaning procedures.
Reference Key
openalex_W7224080098 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal journal of aoac international
Year 2026
DOI
10.1093/jaoacint/qsag098
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.