Electrosurgical septotomy across the full spectrum of aortic dissection

Clicks: 5
ID: 333280
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #53 of 56 articles by views in european journal of cardio-thoracic surgery : official journal of the european association for cardio-thoracic surgery

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Objectives Transcatheter electrosurgical septotomy divides the dissection membrane to reconstitute a single aortic lumen. Reported experience is largely confined to chronic post-dissection aneurysms. We assessed the technique across the full spectrum of descending aortic dissection, including stand-alone treatment of malperfusion. Methods Retrospective intention-to-treat analysis of 21 consecutive patients scheduled for septotomy between June 2022 and May 2026. The membrane was crossed by needle re-entry and divided with an electrified through-and-through guidewire at 40–60 W under fluoroscopy, without routine intravascular ultrasound or image fusion. A perfused-lumen index (perfused lumen divided by total aortic diameter) was measured before and after the procedure. Results Septotomy was performed in 20 of 21 patients (technical success 95% on an intention-to-treat basis). Indications were landing-zone preparation (57%), malperfusion (33%), preparation for open repair and true-lumen collapse. Malperfusion resolved in all 7 patients treated for that indication, and the perfused-lumen index rose from a median of 0.16 to 0.98 (18 patients, P < 0.001). There was no stroke, spinal cord ischaemia or retrograde type A dissection. Thirty-day, in-hospital and overall mortality were 10%, 14% and 19%, with one fatal delayed aortic rupture and no intraprocedural death. Three unplanned reinterventions occurred; median follow-up was 5.1 months. Conclusions Electrosurgical septotomy was feasible across the full spectrum of aortic dissection and, in selected patients, as stand-alone treatment for malperfusion, using standard electrosurgical equipment. Given the small heterogeneous cohort and short follow-up, these findings demonstrate feasibility rather than durability.
Reference Key
openalex_W7223134190 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Gabriel Weiss, Hubert Trnka, Sebastian Tauber, Emely Manville, Zsuzsanna Arnold, Bernhard Michael Winkler, Sandra Folkmann, Martin Grabenwöger
Journal european journal of cardio-thoracic surgery : official journal of the european association for cardio-thoracic surgery
Year 2026
DOI
10.1093/ejcts/ezag246
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.