Motion-corrected Noise2Noise denoising for structural analysis of cells and tissues with (cryo-)FIB/SEM

Clicks: 6
ID: 332565
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #940 of 953 articles by views in BMC Bioinformatics

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 953 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
MOTIVATION: (Cryo-)FIB/SEM enables three-dimensional (3D) ultrastructural analysis of cells and tissues at nanoscale resolution. However, its characteristically low signal-to-noise ratio severely hinders interpretation of the volume data. Noise2Noise has emerged as a state-of-the-art denoising paradigm with outstanding performance in 3D electron microscopy -particularly cryo-ET- but its direct application to (cryo-)FIB/SEM remains unfeasible due to the inherent acquisition workflows. RESULTS: A method to enable Noise2Noise denoising in (cryo-)FIB/SEM is introduced. The input volume is split into even and odd slices followed by the application of motion correction methods to estimate and compensate for the structural differences between the two subvolumes. The resulting motion-corrected subvolumes are then used to train the Noise2Noise model, which is ultimately applied to denoise the original volume. Representative (cryo-)FIB/SEM volumes have been used to validate the method and to demonstrate the critical importance of the motion correction stage for volumes with a slice thickness greater than 10 nm. AVAILABILITY AND IMPLEMENTATION: Code is available at https://github.com/microscopy-processing/N2N-REO and https://doi.org/10.5281/zenodo.22303478. SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.
Reference Key
openalex_W7222740007 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Vicente González-Ruíz, José‐Jesús Fernández
Journal BMC Bioinformatics
Year 2026
DOI
10.1093/bioinformatics/btag765
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.