Multi-class Identification and Quantification of Breast Implant-related Complications in Ultrasonography Using a Pathology-informed Lesion Graph: A Deep Learning Development and Validation Study

Clicks: 19
ID: 332037
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #89 of 132 articles by views in Aesthetic surgery journal

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 132 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
BACKGROUND: Breast ultrasonography (US) is cost-effective for detecting breast implant-related complications, but its reliability remains highly operator-dependent. OBJECTIVES: This study developed and validated a deep learning model for the automated multi-class identification and quantitative evaluation of breast implant complications (rupture, capsular contracture, and hematoma). METHODS: We retrospectively analyzed 14,679 breast US images across 1,022 breast implant sequences from 908 patients. The proposed architecture integrates multiscale visual encoding, automated probe position mapping, and a pathology-informed mask graph layer with a Gradient Reversal Layer for lumen adversarial debiasing. Four convolutional backbones were benchmarked using an independent patient-level test dataset (N=197 implants). RESULTS: The optimized DenseNet-based framework achieved 96.97% balanced accuracy with expert-guided spatial priors and 88.67% under autonomous baseline conditions. The model yielded 100% sensitivity for normal, rupture, and hematoma cohorts, and 87.88% sensitivity for capsular contracture; minor false-negatives were traced to morphological heterogeneity and coexisting pathologies. Furthermore, the system extracted quantitative morphometric profiles, yielding a mean relative capsule thickness of 2.4±0.4% for capsular contractures and a mean relative fluid area of 13.9±6.4% for hematomas. CONCLUSIONS: The proposed multiscale model delivers a comprehensive, clinical-grade output, comprising accurate complication classification, five-zone spatial localization, and objective morphometric metrics, while mitigating operator dependency. This system holds strong potential as an accessible, high-performance decision support tool for long-term safety screening of patients with breast implants.
Reference Key
openalex_W7221329072 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal Aesthetic surgery journal
Year 2026
DOI
10.1093/asj/sjag221
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.