Multi-class Identification and Quantification of Breast Implant-related Complications in Ultrasonography Using a Pathology-informed Lesion Graph: A Deep Learning Development and Validation Study

Clicks: 5
ID: 332037
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #104 of 114 articles by views in Aesthetic surgery journal

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
BACKGROUND: Breast ultrasonography (US) is cost-effective for detecting breast implant-related complications, but its reliability remains highly operator-dependent. OBJECTIVES: This study developed and validated a deep learning model for the automated multi-class identification and quantitative evaluation of breast implant complications (rupture, capsular contracture, and hematoma). METHODS: We retrospectively analyzed 14,679 breast US images across 1,022 breast implant sequences from 908 patients. The proposed architecture integrates multiscale visual encoding, automated probe position mapping, and a pathology-informed mask graph layer with a Gradient Reversal Layer for lumen adversarial debiasing. Four convolutional backbones were benchmarked using an independent patient-level test dataset (N=197 implants). RESULTS: The optimized DenseNet-based framework achieved 96.97% balanced accuracy with expert-guided spatial priors and 88.67% under autonomous baseline conditions. The model yielded 100% sensitivity for normal, rupture, and hematoma cohorts, and 87.88% sensitivity for capsular contracture; minor false-negatives were traced to morphological heterogeneity and coexisting pathologies. Furthermore, the system extracted quantitative morphometric profiles, yielding a mean relative capsule thickness of 2.4±0.4% for capsular contractures and a mean relative fluid area of 13.9±6.4% for hematomas. CONCLUSIONS: The proposed multiscale model delivers a comprehensive, clinical-grade output, comprising accurate complication classification, five-zone spatial localization, and objective morphometric metrics, while mitigating operator dependency. This system holds strong potential as an accessible, high-performance decision support tool for long-term safety screening of patients with breast implants.
Reference Key
openalex_W7221329072 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Hyokyung Yoo, Byeong Soo Kim, Jae Jin Ock, Ki Yong Hong, Chang Hak, Sungwan Kim
Journal Aesthetic surgery journal
Year 2026
DOI
10.1093/asj/sjag221
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.