Evaluating Post-Analytical Stability of Blood Ethanol Samples Using Headspace-GC-FID

Clicks: 22
ID: 331938
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #40 of 64 articles by views in journal of analytical toxicology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
The analysis and determination of blood alcohol concentration (BAC) is a cornerstone test in forensic toxicology that is well researched. The purpose of this study was to determine the post analytical stability of blood ethanol obtained from re-injected vials via Agilent dual column headspace-GC-FID. Over 6 months and 22 individual batch analyses, 303 samples were prepared and analyzed using Headspace-GC-FID for the presence of blood ethanol using 0.02% n-propanol as an internal standard. Each individual batch was re-injected after storage at room temperature for 72 hours to mimic a typical weekend absence. Ethanol signal response, n-propanol signal response and measured blood ethanol concentration were evaluated for stability in terms of percent change. Sample population consisted of negative human blood fortified with known concentrations of ethanol via certified reference material purchased from accredited vendors (n = 187) in the form of calibrators and controls, as well as unknown post-mortem and ante-mortem blood samples submitted to the Nassau County Medical Examiner's Office Department of Forensic Toxicology (n = 116). All samples were tested using similar conditions and internal standard. Significant differences were observed in the signal response for both n-propanol (p<.001) and ethanol (p<.001) between the two test groups however, there was a non-significant difference in measured BAC between the two groups t(302) = 0.3, p = 0.780, d = 0.016. Results suggest very little effect of re-injection after 72-hour storage at room temperature on measured blood ethanol concentration using headspace GC-FID. While there was significant loss of ethanol and internal standard on reinjection, the calculated ethanol concentration was unaffected due to the similar properties of both volatile measurands as well as the consistency of the response ratio of ethanol:n-propanol in reinjected vials. In addition, the observed differences in measured BAC on re-injection were well within the NCME's measurement uncertainty of 11% at k = 3.
Reference Key
openalex_W7221195144 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors David Cook, Jarrad Wagner
Journal journal of analytical toxicology
Year 2026
DOI
10.1093/jat/bkag089
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.