Deep learning with ultrasonography: automated classification of liver fibrosis using a deep convolutional neural network.
Clicks: 385
ID: 33178
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
78.1
/100
385 views
276 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #6 of 34 articles by views in European radiology
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The aim of this study was to develop a deep convolutional neural network (DCNN) for the prediction of the METAVIR score using B-mode ultrasonography images.Datasets from two tertiary academic referral centers were used. A total of 13,608 ultrasonography images from 3446 patients who underwent surgical resection, biopsy, or transient elastography were used for training a DCNN for the prediction of the METAVIR score. Pathological specimens or estimated METAVIR scores derived from transient elastography were used as a reference standard. A four-class model (F0 vs. F1 vs. F23 vs. F4) was developed. Diagnostic performance of the algorithm was validated on a separate internal test set of 266 patients with 300 images and external test set of 572 patients with 1232 images. Performance in classification of cirrhosis was compared between the DCNN and five radiologists.The accuracy of the four-class model was 83.5% and 76.4% on the internal and external test set, respectively. The area under the receiver operating characteristic curve (AUC) for classification of cirrhosis (F4) was 0.901 (95% confidence interval [CI], 0.865-0.937) on the internal test set and 0.857 (95% CI, 0.825-0.889) on the external test set, respectively. The AUC of the DCNN for classification of cirrhosis (0.857) was significantly higher than that of all five radiologists (AUC range, 0.656-0.816; p value < 0.05) using the external test set.The DCNN showed high accuracy for determining METAVIR score using ultrasonography images and achieved better performance than that of radiologists in the diagnosis of cirrhosis.• DCNN accurately classified the ultrasonography images according to the METAVIR score. • The AUROC of this algorithm for cirrhosis assessment was significantly higher than that of radiologists. • DCNN using US images may offer an alternative tool for monitoring liver fibrosis.
| Reference Key |
lee2019deepeuropean
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Lee, Jeong Hyun;Joo, Ijin;Kang, Tae Wook;Paik, Yong Han;Sinn, Dong Hyun;Ha, Sang Yun;Kim, Kyunga;Choi, Choonghwan;Lee, Gunwoo;Yi, Jonghyon;Bang, Won-Chul; |
| Journal | European radiology |
| Year | 2019 |
| DOI |
10.1007/s00330-019-06407-1
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.