Data curation and cross-instrument variability influence GC-MS-based metabolite profiling of endophytic fungi associated with Moringa oleifera

Clicks: 38
ID: 331453
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #59 of 208 articles by views in Journal of applied microbiology

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 208 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
AIM: This study presents an exploratory assessment of volatile and semi-volatile metabolites produced by endophytic fungi associated with Moringa oleifera using gas chromatography-mass spectrometry (GC-MS), emphasising metabolite occurrence and analytical consistency. METHODS AND RESULTS: Twelve endophytic fungal isolates were recovered from leaf and twig tissues and putatively identified by morphology and internal transcribed spacer (ITS) sequencing. Each isolate was cultivated as a single, unreplicated 1 L shake-flask culture in Sabouraud dextrose broth (28°C, 120 rpm, 12-20 days), and the cell-free broth extracted with an equal volume of n-hexane. Initial spectral matching generated a broad set of compound annotations. Curation removed analytical artefacts, contaminants (including siloxanes and phthalates), and low-confidence identifications, leaving a small set of biologically plausible, tentatively identified metabolites, among them furfuryl alcohol, kojic acid, lauric acid, palmitic acid, and undecylenic acid. Cross-instrument comparison on two GC-MS platforms revealed substantial variability when instrument-specific libraries were used; commercial library matching returned twelve tentatively identified metabolites in one extract and six in the other on the second platform, and none on the first. No compound was recovered on both platforms. CONCLUSION: Metabolite annotation proved highly sensitive to instrument configuration and to the choice of spectral library: the same extracts yielded entirely non-overlapping compound lists on two platforms from the same manufacturer using the same detector type and ionisation energy. These findings highlight the importance of stringent data curation, cautious spectral interpretation, and analytical standardisation in GC-MS-based metabolomics. All assignments are tentative, based on library matching without co-injection of authentic standards.
Reference Key
openalex_W7220735346 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Markwo Ali, Bekri Melka Abdo, Salar Hafez-Ghoran, Dorcas Osei‐Safo, Robert Kingsford-Adaboh, Atia-tul Wahab, Muhammad Iqbal CHOUDHARY
Journal Journal of applied microbiology
Year 2026
DOI
10.1093/jambio/lxag249
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.