A paper-based platform with a pencil-drawn dual amperometric detector for the rapid quantification of ortho-diphenols in extravirgin olive oil.
Clicks: 251
ID: 33082
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
67.0
/100
251 views
203 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #48 of 84 articles by views in analytica chimica acta
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A simple, sensitive and fast responding device is described for the discrimination of hydrophilic ortho-diphenols, whose presence in abundant enough amounts is typical for extra virgin olive oils (EVOOs), from hydrophilic mono-phenols instead present in almost all vegetable oils. It consists of a dual electrode detector pencil-drawn at the end of a paper microfluidic channel, defined by hydrophobic barriers, where samples of these antioxidants, extracted from vegetable oils by a 80:20% v/v acetonitrile/water mixture, were applied. Thin-layer chromatographic runs conducted by using a 0.01 M HSO + 1 M KCl running buffer allowed the selective detection of hydrophilic ortho-diphenols by profiting from the fact that they undergo reversible oxidation at less positive potentials than those required by monophenols for displaying their irreversible anodic process. On this basis, a potential for the oxidation of hydrophilic ortho-diphenols was applied to the upstream pencil-drawn electrode (W) (at which a minor fraction of mono-phenols was also oxidized), while a potential for the reverse process involving the sole product (ortho-quinones) of the reversible oxidation of ortho-diphenols was imposed at the downstream pencil-drawn working electrode (W). Thus, cathodic peak currents linearly dependent on analyte concentrations could be recorded at W which led to a satisfactory detection limit (8 μM, equivalent to 1.23 mg/L) even when working electrodes W and W with same dimensions were employed. Improved sensitivities and lower detection limits were achieved by increasing the dimensions of W with respect to W, thanks to the improvement of the collection efficiency. Throughout this investigation, hydroxytyrosol (HTy) and tyrosol (Ty) were adopted as models of ortho-diphenols and mono-phenols, respectively, in view of their abundant presence in EVOOs. Real samples of EVOO from different production companies, of a simple olive oil and of a sunflower oil were analyzed. Different hydrophilic ortho-diphenol contents were found in EVOO samples (up to 40.8 mg/kg), while only a negligible amount turned out to be present in simple olive oil. No trace of these antioxidants were instead found in sunflower oil, as expected. All concentrations found were in good agreement with those detected by a more frequently employed spectrophotometric method used for the sake of comparison.
| Reference Key |
dossi2017aanalytica
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Dossi, Nicolò;Toniolo, Rosanna;Impellizzieri, Flavia;Tubaro, Franco;Bontempelli, Gino;Terzi, Fabio;Piccin, Evandro; |
| Journal | analytica chimica acta |
| Year | 2017 |
| DOI |
S0003-2670(16)31322-8
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org