Preoperative Parathyroid Imaging in CKD-Related Secondary Hyperparathyroidism: A Systematic Review and Diagnostic Test Accuracy Network Meta-analysis
Clicks: 10
ID: 330796
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
2.7
/100
10 views
9 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #153 of 181 articles by views in clinical kidney journal
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 181 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Abstract Background and Aims In secondary hyperparathyroidism (SHPT), imaging must characterize multifocal disease and identify ectopic or supernumerary tissue before surgery, but the comparative accuracy and optimal hierarchy of available modalities remain uncertain. We compared the main preoperative imaging techniques used for parathyroid localization in patients with chronic kidney disease (CKD). Methods MEDLINE, Embase and Web of Science were searched from inception through 31 May 2026 for gland-, lesion- or site-level diagnostic accuracy studies in adults with chronic kidney disease, kidney failure or kidney transplantation, using surgical and/or histopathological confirmation. An arm-based Bayesian bivariate network meta-analysis jointly estimated sensitivity and specificity for ultrasonography (US), non-subtraction ⁹⁹ᵐTc-MIBI planar scintigraphy, ⁹⁹ᵐTc-MIBI SPECT/CT and ¹⁸F-fluorocholine (¹⁸F-FCH) PET/CT. Balanced accuracy and comparative effects versus US were also estimated. Risk of bias was assessed using QUADAS-3. Results Ten studies including 479 participants contributed 24 test arms. Estimated sensitivity was 89.6% (95% credible interval [CrI] 81.9–94.5) for ¹⁸F-FCH PET/CT, 68.8% (56.0–79.2) for MIBI SPECT/CT, 64.2% (51.0–75.6) for US and 45.9% (32.8–59.4) for planar MIBI. Specificity estimates ranged from 76.4% to 83.8% and were imprecise. Compared with US, ¹⁸F-FCH PET/CT showed higher sensitivity (odds ratio 4.83, 95% CrI 3.20–7.48) and balanced accuracy (+11.9 percentage points, 95% CrI 0.1–20.6), with no clear specificity difference. Findings were directionally consistent in sensitivity analyses. Conclusions ¹⁸F-FCH PET/CT had the highest estimated sensitivity and balanced accuracy, although evidence was limited and specificity remained uncertain. A clinically guided hierarchy beginning with US and progressing to ¹⁸F-FCH PET/CT, may improve comprehensive glandular mapping and support multidisciplinary operative planning in SHPT. 4D-CT and dual-isotope scintigraphic techniques also appear promising as alternative or complementary strategies, although SHPT-specific evidence remains limited and requires further dedicated comparative studies.
| Reference Key |
openalex_W7215081041
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Daniele Vetrano, Simona Barbuto, Anna Mistretta, Guido Zavatta, Francesco Aguanno, Paolo Mastromauro, Giorgia Comai, Giulia Molinari, Guido Marzocchi, Giuseppe Mercante, Uberto Pagotto, Carla Serra, Stefano Fanti, Luigi Lovato, Gaetano La Manna, Giuseppe Cianciolo |
| Journal | clinical kidney journal |
| Year | 2026 |
| DOI |
10.1093/ckj/sfag344
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.