A cotton thread fluidic device with a wall-jet pencil-drawn paper based dual electrode detector.
Clicks: 205
ID: 33073
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
74.0
/100
205 views
167 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #65 of 84 articles by views in analytica chimica acta
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A simple and sensitive device is presented based on the use of pencil-drawn paper based electrochemical detector placed at the end of a cotton thread fluidic channel in wall-jet configuration. This innovative and fast responding electroanalytical system can be adopted for both single and dual electrode electrochemical detection, this last achieved by applying two different potentials at two independent working electrodes drawn on the opposite faces of the paper based detector. Its performance was preliminarily optimized by adopting hexacyanoferrate(II) as probe species undergoing reversible electrochemical processes. These devices were then used for the single electrode detection of ascorbic acid in aqueous samples and the dual electrode detection of orthodiphenols in extra virgin olive oils (EVOOs). In fact, these devices enable hydrophilic orthodiphenols, typically present in EVOOs (extracted by a 80:20% v/v acetonitrile/water mixture), to be discriminated from hydrophilic monophenols instead present in almost all vegetable oils. Flow-injections runs were conducted by using a 0.01 M HSO + 0.5 KCl running electrolyte allowing the rapid and selective detection of hydrophilic orthodiphenols with satisfactory sensitivity and a low enough detection limit (2 μM). Different real samples of EVOOs and sunflower oils were analyzed. Abundant enough contents of orthidiphenols were found in EVOO samples, while no trace of these antioxidants was found in sunflower oils.
| Reference Key |
dossi2018aanalytica
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Dossi, Nicolò;Toniolo, Rosanna;Terzi, Fabio;Sdrigotti, Nicola;Tubaro, Franco;Bontempelli, Gino; |
| Journal | analytica chimica acta |
| Year | 2018 |
| DOI |
S0003-2670(18)30826-2
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.