Analysis of out-of-hospital cardiac arrest location and public access defibrillator placement in Metropolitan Phoenix, Arizona.
Clicks: 232
ID: 32977
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
74.3
/100
232 views
191 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #21 of 37 articles by views in Resuscitation
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Automated external defibrillators (AEDs) improve outcomes from out-of-hospital cardiac arrest (OHCA) but are infrequently used. We sought to compare the locations of OHCAs and AEDs in metropolitan Phoenix, Arizona.Public location OHCAs and AEDs were geocoded utilizing a statewide OHCA database (1/2010-12/2012) and AED registry. OHCAs were mapped using kernel-density estimation and overlapped with AED placements. Spearman's rho was obtained to determine the correlation between OHCA incidents and AED locations.A total of 654 consecutive public location OHCAs and all 1704 non-medical facility AEDs registered in the study area were included in the analysis. High OHCA incident areas lacking AEDs were identified in the kernel-density surface map. OHCA event/AED correlation analysis showed a weak correlation (Spearman's rho=0.283; p=0.002). Events occurred most frequently at locations categorized as "In Cars/Roads/Parking lots" (190/654, 29.1%) and there were no identified AEDs for these areas. AEDs were placed most frequently in "Public business/Office/Workplace" and cardiac arrests occurred with the second highest frequency in this location type.There was a weak correlation between OHCA events and deployed AEDs. It was possible to identify areas where OHCAs occurred frequently but AEDs were lacking. The ability to correlate the sites of OHCAs and AED locations is a necessary step toward improving the effectiveness of public access defibrillation.
| Reference Key |
moon2015analysisresuscitation
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Moon, Sungwoo;Vadeboncoeur, Tyler F;Kortuem, Wesley;Kisakye, Marvis;Karamooz, Madalyn;White, Bernadette;Brazil, Paula;Spaite, Daniel W;Bobrow, Bentley J; |
| Journal | Resuscitation |
| Year | 2015 |
| DOI |
10.1016/j.resuscitation.2014.10.029
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.