Non-invasive assessment of left atrial activation using lead V8 during Bachmann bundle pacing

Clicks: 31
ID: 329720
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #22 of 137 articles by views in EP Europace

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 137 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background and aims Bachmann bundle pacing (BBP) improves atrial synchrony by advancing LA activation, but quantifying inter-atrial synchronization remains challenging. This study evaluated whether lead V8 reflects posterolateral LA activation time and whether lead V8 can be used to assess the effect of BBP on LA activation. Methods Consecutive patients undergoing an electrophysiology study and ablation (Cohort 1) or BBP lead implantation (Cohort 2) were prospectively enrolled. Surface ECGs were recorded with the V5 electrode repositioned to the V8 location (2 cm below the inferior left scapula). LA activation was determined using the steepest negative downslope of the P-wave (NDAT-P-V8). Iso-V8 was defined as the time from P-wave onset to first positive deflection in lead V8. In Cohort 1, a coronary sinus (CS) catheter invasively determined activation timing at the posterolateral LA (mitral isthmus region). In Cohort 2, NDAT-P-V8 and iso-V8 were used to assess the effect of BBP on LA activation. Results In Cohort 1 (n=50), NDAT-P-V8 strongly correlated with the latest CS activation (r = 0.94, p<0.001). In Cohort 2 (n=50), lead V8 facilitated intra-procedural assessment of LA activation. IAB was corrected in 20/23 (87%), accompanied by shortening of NDAT-P-V8 (from 120±25ms to 82±17ms, p<0.001) and iso-V8 (from 51±22ms to 18±17ms, p<0.001), consistent with earlier LA activation. Conclusion NDAT-P-V8 closely reflects the invasively determined timing of the posterolateral LA activation and provides a simple non-invasive marker to assess the effect of BBP on LA activation. Lead V8 may therefore help to assess and optimize atrial activation with BBP.
Reference Key
openalex_W7214280038 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal EP Europace
Year 2026
DOI
10.1093/europace/euag276
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.