Development and Validation of an LC–MS/MS Method for the Detection of Substituted Phenethylamines and Phenidates Designated as Temporary Narcotics in Urine

Clicks: 10
ID: 329425
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #53 of 61 articles by views in journal of analytical toxicology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Novel psychoactive phenethylamines and phenidates are synthetically designed analogs of conventional substances such as 3,4-methylenedioxymethamphetamine (MDMA), amphetamine, and methylphenidate, developed to circumvent existing drug regulations. In Korea, the abuse of these substances has increased, particularly among habitual users and newly addicted younger individuals. To address this issue, new substances are regulated through the analog legislation and the temporary narcotic designation system. In this study, liquid chromatography–tandem mass spectrometry (LC–MS/MS) method using solid-phase extraction (SPE) was developed and validated for the simultaneous determination of 13 substituted phenethylamines and 5 substituted phenidates in human urine. The target analytes included 5-MAPDB, BDB, 4-FEA, PMEA, 3-FPM, 25iP-NBOMe, 2C-N, 2C-TFM, 30C-NBOMe, 3C-P, 4-MMA-NBOMe, DOI, and 2C-H, as well as 4-MeTMP, 4F-EPH, 4F-MPH, IPPH, and HDEP-28. No interfering peaks were observed at the retention times of analytes and internal standards. Linearity was confirmed over analyte-specific concentration within the overall range of 0.1–100 ng/mL, with coefficient of determination (r2) exceeding 0.995. The limits of detection and quantification were 0.001–0.1 ng/mL and 0.1–0.2 ng/mL, respectively. Accuracy and precision, expressed as bias and coefficient of variation (CV), were within ±10% and <10%, respectively. The CVs for matrix effects and extraction efficiencies were approximately 10%, and the extraction efficiencies exceeded 70%, confirming the reliability of the method for forensic applications. The validated method enables simultaneous determination of substituted phenethylamines and phenidates in urine and facilitates prompt positive identification in forensic casework. In addition, the structural information, MRM conditions, and analytical method validation results presented in this study can serve as a basis for expanding research on substances with similar core structures, which is expected to strengthen regulatory responses to evolving drug trends.
Reference Key
openalex_W7214061201 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Sujin Jeong, Yoseob Kim, Seojin Kang, Chae Eun Lee, Moonhee Jang, Hyung Min Kim
Journal journal of analytical toxicology
Year 2026
DOI
10.1093/jat/bkag086
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.