TricValve system implantation in patients with cardiac implantable electronic devices: A multicentre observational study

Clicks: 23
ID: 328802
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #31 of 49 articles by views in european journal of cardio-thoracic surgery : official journal of the european association for cardio-thoracic surgery

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
OBJECTIVES: Tricuspid regurgitation (TR) is associated with high morbidity and mortality. The TricValve bicaval valve system has emerged as a transcatheter option for patients with severe symptomatic TR who are not candidates for surgery or orthotopic interventions. However, its safety in patients with pre-existing cardiac implantable electronic devices (CIED) remains uncertain due to potential lead-related complications. This study aims to evaluate the feasibility and safety of TricValve implantation in patients with pre-existing CIED, with particular focus on lead-related complications and the need for lead extraction or repositioning. METHODS: We conducted a multicentre retrospective study including 65 patients with pre-implanted CIED who underwent TricValve implantation between May 2023 and November 2024 at 23 international centres. Pre-procedural computed tomography and echocardiography were analyzed to assess device interaction, lead positioning, and complications. The primary endpoint was procedural safety, including lead-related events and the need for lead extraction or repositioning during intervention. Secondary endpoints included echocardiographic outcomes, CIED/non-CIED-related complications and survival during follow-up of 159 days (IQR 60-358 days). RESULTS: TricValve implantation was technically successful in all patients (100%). Periprocedural no lead extraction or repositioning was required. Lead-related complications occurred in 4 patients (6.2%). No procedural deaths or TricValve malfunctions were observed. Post-implantation imaging confirmed stable lead positioning in all remaining cases. CONCLUSIONS: TricValve implantation in patients with pre-existing CIED appears feasible. Lead-related complications during early follow-up were rare, manageable, and did not compromise device function or procedural success. Our data do not support routine prophylactic lead extraction before TricValve implantation.
Reference Key
openalex_W7213307756 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Kira Osipenko, Iuliana Coti, Paul Werner, Amila Kahrovic, Luis Nombela Franco, Ignacio J Amat Santos, Amir A Mahabadi, Christian Frerker, Federico De Marco, Jan Althoff, Antonio Mangieri, Javier Martín Moreiras, Nikola Pavlović, Joachim Schöfer, Ulrich Schäfer, Eike Tigges, Christoph Wilde, Jörg Hausleiter, Omar Abdul-Jawad Altisent, Maurizio Taramasso, Luis Fernando Pajin Valbuena, Joško Bulum, Santiago Ordóñez, Martin Swaans, João Silva Marques, Boris Dickmann, Birgit Zirngast, Daniel Zimpfer, Martin Andreas
Journal european journal of cardio-thoracic surgery : official journal of the european association for cardio-thoracic surgery
Year 2026
DOI
10.1093/ejcts/ezag224
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.