Evaluating Substitution of Hazardous Solvents in USP Monograph HPLC Methods

Clicks: 17
ID: 328518
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #313 of 368 articles by views in journal of aoac international

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 368 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
BACKGROUND: Hazardous solvents, such as dichloromethane (DCM), n-hexane, and acetonitrile (ACN), are widely used in HPLC methods, posing significant health and environmental risks. OBJECTIVE: To evaluate the feasibility and impact of substituting hazardous solvents with greener alternatives in USP monograph methods. METHODS: Six high-impact solvents were identified from USP-NF monographs. Two representative monographs per solvent were selected. Substitution strategies were assessed, and performance was compared using system suitability and sample acceptance criteria. Greenness improvement was evaluated using the Analytical GREEnness (AGREE) metric. RESULTS: Performance remained equivalent across all twelve substitution cases. In almost every instance, only the mobile phase required modification, either by direct substitution or by adjusting the solvent-to-buffer ratio, except for one case that required a minor adjustment in column temperature. The AGREE Greenness metric increased by 18-65% in ten out of twelve cases; for n-hexane, improvements were modest at just 6% when replaced with n-heptane but exceeded 40% when substituted with supercritical CO₂. CONCLUSIONS: Greener solvents are highly likely to replace hazardous solvents used in compendial chromatography methods without loss of performance. HIGHLIGHTS: Demonstrated performance equivalency for greener solvent substitutions; Quantified greenness improvements using AGREE; Discussed strategies to implement greener solvents in USP monograph methods.
Reference Key
openalex_W7212267157 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Weidong Zhao, Koushik Mondal, Praveen Thakur, David Mande, Nagaraju Katepally, Parise Naga Malleswari, Lakshmi Kanth Juluru, Suresh Kumar Sheik, YVS Veerendra, Arunima Pola, Greg Winter, Paolo Lecchi, Mrunal A. Jaywant, Michael Ambrose
Journal journal of aoac international
Year 2026
DOI
10.1093/jaoacint/qsag071
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.