Robust prediction of mandarin fruit quality from repeated portable visible-near infrared measurements using error covariance penalized regression

Clicks: 31
ID: 327955
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #15 of 40 articles by views in Food Quality and Safety

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract With the development of spectrometer miniaturization, portable visible-near infrared (Vis-NIR) devices provide new opportunities for on-site and real-time fruit quality detection. However, under practical complex measurement scenarios, the measurement stability and predictive robustness of portable devices remain limited. Soluble solids content (SSC) is widely used as a representative indicator in fruit quality evaluation and Vis-NIR quantitative analysis. To improve the predictive performance of portable Vis-NIR models, error covariance penalized regression (ECPR) was employed to explicitly incorporate the error covariance matrix estimated from repeated Vis-NIR measurements into SSC prediction modeling. Two mandarin cultivars, Panzhihua Orah mandarin and Australian mandarin, were investigated using repeated spectra acquired by a portable Vis-NIR spectrometer. Experimental results demonstrated that ECPR consistently outperformed conventional regression models. With optimal spectral pretreatment, ECPR achieved coefficients of determination of 0.949 and 0.841, with corresponding root mean square errors of prediction of 0.192 and 0.441, respectively. These results indicate that ECPR modeling based on the covariance structure of repeated measurement errors provides an effective strategy for improving the predictive accuracy and robustness of portable Vis-NIR models.
Reference Key
openalex_W7208815157 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal Food Quality and Safety
Year 2026
DOI
10.1093/fqsafe/fyag069
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.