Detecting and characterizing restricted diffusion with accessible magnetic field gradients

Clicks: 18
ID: 327861
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #90 of 151 articles by views in PNAS nexus

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 151 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract For over 50 years, diffusion magnetic resonance (dMR) has been employed in numerous studies on characterizing chemical compounds, porous media, and biological tissues. These studies have almost exclusively employed the Stejskal-Tanner (ST) pulse sequence, which is sensitive to the ensemble average propagator (EAP). EAP is a compromised version of the true diffusion propagator---a quantity that fully describes the diffusion process in any system and holds exquisite information that can be used to characterize complex samples. Recently, a new diffusion sensitization method was proposed, here referred to as PROP, and was shown to be capable of acquiring the true diffusion propagator in closed pores. However, its adequate use requires a large number of measurements and (consequently) a long acquisition time. Thus, its translation to, e.g., the clinical field, is challenging. Here, we propose a reduced PROP pulse sequence (rPROP) which offers various advantages over the ST sequence. rPROP excels at isolating restricted diffusion thanks to its inherently high diffusion-weighting, yielding an efficient free diffusion filter. We employ rPROP to study different samples, and compare its performance to ST measurements in terms of estimation accuracy and gradient amplitude requirements. Furthermore, we study the capability of rPROP to detect anisotropic diffusion in samples which predominantly feature isotropic diffusion. Finally, we present a method capable of acquiring the mean position distribution (analogous to the EAP attainable via ST data) of particles via MR measurements. We highlight that all signals and images presented in this work were acquired using a benchtop MRI scanner.
Reference Key
openalex_W7208817796 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal PNAS nexus
Year 2026
DOI
10.1093/pnasnexus/pgag293
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.