Pulmonary Vein Isolation Durability in a Randomized Trial comparing Fluoroscopy-only vs. Electroanatomic Mapping Strategies for Pulmonary Vein Isolation With Balloon-in-basket Pulsed-field Ablation

Clicks: 18
ID: 327517
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #99 of 136 articles by views in EP Europace

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 136 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background Data on long-term durability of pulmonary vein isolation (PVI) with newer pulsed field ablation (PFA) platforms and incremental value of electroanatomic mapping (EAM) guidance remain limited. This study evaluated chronic PVI durability following ablation with a balloon-in-basket PFA catheter and compared outcomes of fluoroscopy-only versus fluoroscopy plus EAM workflows. Methods In this prospective, single-center trial, consecutive patients with paroxysmal or persistent atrial fibrillation (AF) underwent de novo PVI with a balloon-in-basket PFA catheter. Patients were randomized 1:1 to fluoroscopy-only or fluoroscopy plus EAM workflow. Systematic invasive remapping was planned >30 days after the index procedure. The dual primary efficacy endpoint was the proportion of pulmonary veins (PVs) and of patients with all PVs durably isolated. The prespecified secondary endpoint was the comparison of procedural characteristics and PVI durability between workflows. Safety outcomes included major adverse events within 30 days of index or remapping procedures. Results Ninety-six patients (67.4 ± 9.2 years, 44.8% female, 57.3% with paroxysmal AF) underwent index ablation. Fluoroscopy time and number of applications were 3.4 [2.4–4.6] minutes and 15 [13–16], respectively. Systematic remapping was performed in 86 patients at a median of 41 days, with per-vein and per-patient durability of 341/350 (97.4%), and 79/86 (91.9%) respectively. PVI durability and chronic remapping parameters were comparable between guidance strategies. No major adverse events occurred. Conclusion A standardized balloon-in-basket PFA workflow for PVI achieved high PVI durability. EAM guidance did not confer additional procedural or durability benefit over fluoroscopy-only guidance.
Reference Key
openalex_W7207819767 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal EP Europace
Year 2026
DOI
10.1093/europace/euag244
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.