Long-term incidence of infective endocarditis according to the type of cardiac implantable electronic device: a nationwide comparison with moderate- and high-risk patient groups

Clicks: 3
ID: 326857
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #87 of 88 articles by views in EP Europace

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
BACKGROUND AND AIMS: According to ESC guidelines, patients with a cardiac implantable electronic device (CIED) are considered at moderate risk of infective endocarditis (IE), irrespective of CIED type. However, comparative data across CIED types and IE risk groups are limited. We examined IE rates according to CIED type compared with moderate- and high-risk groups. METHODS: Danish nationwide registries were used to identify patients with first-time CIED implantation and reference populations at moderate and high risk of IE (2000-2022), based on ESC guidelines. The high-risk group included patients with a left-sided prosthetic valve. Patients with prior IE or left-sided prosthetic valve were excluded from the CIED group. The primary outcome was incident IE within 10 years. RESULTS: The study included 84,171 CIED recipients, 127,966 moderate-risk patients, and 23,505 high-risk patients. Pacemakers were the most common CIED type (74.9%), followed by ICD (16.6%), CRT-D (4.6%), and CRT-P (3.9%). Pacemaker recipients were the oldest (median 78.2 years) and most frail. The 10-year cumulative incidence of IE was lowest in pacemaker recipients (1.0% [95% CI:0.9-1.1]) and highest in CRT-D recipients (2.2% [95% CI:1.7-2.9]). In adjusted analyses, all CIED types were associated with higher IE rates than the moderate-risk group but lower than the high-risk group. CONCLUSION: In this nationwide cohort, IE risk differed across CIED types, highest in CRT-D and lowest in pacemaker recipients. All CIED types were associated with higher risk than moderate-risk patients but lower risk than high-risk patients, supporting ESC classification. CRT-D recipients may warrant further evaluation of preventive strategies.
Reference Key
openalex_W7204596992 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Amna Alhakak, Lauge Østergaard, Mohammed Bakir Ahmad Lafta, Michael Vinther, Berit T. Philbert, Henning Bundgaard, Lars Køber, Emil Loldrup Fosbøl
Journal EP Europace
Year 2026
DOI
10.1093/europace/euag232
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.