82 Proton versus photon stereotactic radiotherapy for brain metastases unsuitable for single-fraction stereotactic radiosurgery: a dosimetric comparison with robustness analysis

Clicks: 18
ID: 326754
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #178 of 287 articles by views in journal of neuro-oncology

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 287 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Introduction Fractionated stereotactic radiotherapy (SRT) is a recognised treatment for brain metastases unsuitable for single-fraction stereotactic radiosurgery, particularly large tumours, lesions near critical structures, or postoperative cavities. Proton beam therapy (PBT) may improve dose conformity and organ-at-risk sparing, although data remain limited. As advances in systemic therapy prolong survival, intracranial re-irradiation may increase, rendering cumulative dose to uninvolved brain clinically relevant. Method We performed a retrospective within-patient dosimetric comparison of pencil beam scanning PBT plans and clinically delivered photon SRT plans in 10 patients treated with hypofractionated SRT at a tertiary neuro-oncology centre in the UK. Photon plans used 1 mm planning target volume (PTV) margins, whereas proton plans employed clinical target volume (CTV)-based robust optimisation incorporating ±1 mm setup and ±3.5% range uncertainty across 14 scenarios. Target coverage and organ-at-risk doses were compared using Wilcoxon signed-rank tests. Results Nominal photon PTV D99% was comparable to robustness-adjusted proton CTV D99% (100.0% vs 100.6%, p = 0.961). Three postoperative cases demonstrated reduced proton coverage under uncertainty adjacent to surgical clips. PBT significantly reduced whole-brain V12 (29.3 cc vs 41.2 cc, p = 0.002) and V5–V10 in all patients. Hippocampal D40% (0.00 Gy vs 0.33 Gy, p = 0.002), brainstem D0.1cc (0.05 Gy vs 2.54 Gy, p = 0.002), and pituitary Dmax (0.00 Gy vs 0.38 Gy, p = 0.004) were also lower. Conclusions PBT preserved target coverage while reducing low-dose exposure to uninvolved brain and critical serial structures. Key benefits included hippocampal sparing and reduction in whole-brain V12, recognised dose–volume parameters linked to neurocognitive function and radionecrosis risk. Careful anatomical selection is essential, particularly in postoperative cavities containing surgical clips where coverage under uncertainty may be compromised. Prospective studies are required to determine whether dosimetric improvements translate into meaningful clinical benefit.
Reference Key
openalex_W7204466550 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal journal of neuro-oncology
Year 2026
DOI
10.1093/neuonc/noag172.028
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.