Thigh abscess following alternate-site continuous glucose monitoring sensor placement

Clicks: 43
ID: 326613
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #74 of 279 articles by views in American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 279 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Purpose To describe a methicillin-susceptible Staphylococcus aureus (MSSA) thigh abscess following alternate-site placement of a continuous glucose monitor (CGM) sensor and to highlight safety considerations associated with off-label device use in patients with poorly controlled diabetes. Summary A 49-year-old man with uncontrolled type 2 diabetes (glycated hemoglobin, 11.3%) was referred to an ambulatory care pharmacist for diabetes management. The patient placed the sensor on his upper thigh due to prior dislodgement from the upper arm. Three days later, the patient presented with a painful, erythematous, fluctuant 4.5 x 5 cm abscess at the sensor insertion site. Initial incision and drainage (I&D) was performed and oral sulfamethoxazole/trimethoprim was prescribed. Four days later, he returned with worsening pain and impaired ambulation requiring repeat I&D. Wound cultures grew MSSA. Management additionally included wound packing, topical mupirocin, and continuation of sulfamethoxazole/trimethoprim, with clinical improvement noted after the second I&D procedure. Cutaneous complications with CGM use are typically mild, infrequent, and most often involve contact or irritant dermatitis rather than infection. Reports of CGM-associated skin infections are rare, and none have been reported following sensor placement at unapproved insertion sites. Conclusion This case underscores the potential for a skin and soft tissue infection following off-label CGM placement, especially in patients with uncontrolled hyperglycemia. Pharmacists play a critical role in reinforcing appropriate device use, identifying early signs of infection, and coordinating interdisciplinary care to mitigate device-related complications.
Reference Key
openalex_W7204572739 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists
Year 2026
DOI
10.1093/ajhp/zxag252
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.