Interactive Hierarchical-Flow Segmentation of Scar Tissue From Late-Enhancement Cardiac MR Images.

Clicks: 256
ID: 32642
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #12 of 16 articles by views in ieee transactions on medical imaging

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
We propose a novel multi-region image segmentation approach to extract myocardial scar tissue from 3-D whole-heart cardiac late-enhancement magnetic resonance images in an interactive manner. For this purpose, we developed a graphical user interface to initialize a fast max-flow-based segmentation algorithm and segment scar accurately with progressive interaction. We propose a partially-ordered Potts (POP) model to multi-region segmentation to properly encode the known spatial consistency of cardiac regions. Its generalization introduces a custom label/region order constraint to Potts model to multi-region segmentation. The combinatorial optimization problem associated with the proposed POP model is solved by means of convex relaxation, for which a novel multi-level continuous max-flow formulation, i.e., the hierarchical continuous max-flow (HMF) model, is proposed and studied. We demonstrate that the proposed HMF model is dual or equivalent to the convex relaxed POP model and introduces a new and efficient hierarchical continuous max-flow based algorithm by modern convex optimization theory. In practice, the introduced hierarchical continuous max-flow based algorithm can be implemented on the parallel GPU to achieve significant acceleration in numerics. Experiments are performed in 50 whole heart 3-D LE datasets, 35 with left-ventricular and 15 with right-ventricular scar. The experimental results are compared to full-width-at-half-maximum and Signal-threshold to reference-mean methods using manual expert myocardial segmentations and operator variabilities and the effect of user interaction are assessed. The results indicate a substantial reduction in image processing time with robust accuracy for detection of myocardial scar. This is achieved without the need for additional region constraints and using a single optimization procedure, substantially reducing the potential for error.
Reference Key
rajchl2014interactiveieee Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Rajchl, Martin;Yuan, Jing;White, James A;Ukwatta, Eranga;Stirrat, John;Nambakhsh, Cyrus M S;Li, Feng P;Peters, Terry M;
Journal ieee transactions on medical imaging
Year 2014
DOI
10.1109/TMI.2013.2282932
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.