Physiologic Mechanisms of Response to Hypoglossal Nerve Stimulation

Clicks: 25
ID: 326408
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #22 of 198 articles by views in Sleep & breathing = Schlaf & Atmung

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 198 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Study Objectives To evaluate the relationship between physiologic mechanisms under drug-induced sleep endoscopy (DISE) and polysomnographic response to hypoglossal nerve stimulation (HGNS). Materials and Methods In an NIH-funded interventional trial, thirty subjects with HGNS devices underwent DISE with pneumotachometer, pharyngeal manometry, and positive airway pressure titration. On the previous night, subjects underwent a split-night polysomnogram (first portion without HGNS and second at a single clinically-determined voltage) in the supine position. Responder status was determined by a 50% reduction in supine apnea-hypopnea index (AHI). Groups (responders vs. nonresponders) were compared using the Wilcoxon Rank Sum Test, and Spearman’s rho was used to assess correlations between physiologic mechanisms under DISE and polysomnographic response. Results Patients (n = 30) were generally older (64.3 ± 8.9 years), female (56.7%), and overweight (BMI 28.1 ± 3.1 kg/m2) with severe OSA (supine AHI 47.7 ± 25.4 events/hour). Among 14 responders and 16 nonresponders, there was no statistical difference in baseline collapsibility (PhOP, 5.9 ± 2.4 vs 7.2 ± 3.7 cmH2O, p = 0.39) or baseline inspiratory epiglottic pressure (Pepi,-17.2 ± 9.0 vs -18.6 ± 12.8 cmH2O, p = 0.99). Improvements in collapsibility (rho = 0.70, p = 0.0001) and inspiratory epiglottic pressure (rho = -0.70, p = 0.0001) with HGNS were strongly associated with reduction in supine AHI. Conclusions In this small interventional study, decreases in collapsibility and effort during DISE are markers of clinical response to HGNS therapy. Our novel findings demonstrate responses to acute physiologic interventions during DISE translate to natural sleep outcomes.
Reference Key
openalex_W7204159762 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Linda C. Magaña, Yash Dixit, Bruno Saconi, Brendan T Keenan, Everett G. Seay, Alan R. Schwartz, Raj C. Dedhia
Journal Sleep & breathing = Schlaf & Atmung
Year 2026
DOI
10.1093/sleep/zsag227
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.