Functional Performance, Subject-body Perception, and Safety Following Multi-muscle Electromuscular Stimulation: A Randomized Controlled Study

Clicks: 16
ID: 326249
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #30 of 82 articles by views in Aesthetic surgery journal

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Background Electromuscular stimulation (EMS) and high-intensity focused electromagnetic technologies are widely used for non-invasive muscle strengthening and body contouring. Most available EMS devices induce repetitive contractions of isolated muscle groups resulting in increased muscle thickness and improved aesthetic outcome. However, the current literature is lacking evidence to support functional performance gain following EMS treatments. Objectives To evaluate functional performance outcomes following treatment with a novel EMS technology. based on synchronized multi-muscle activation and regulated contraction duty cycles. Methods Thirty-eight healthy adult subjects were equally randomized to treatment and blank control cohorts. The study was conducted between July 2025 and January 2026. The treatment protocol included six weekly sessions targeting abdominal, quadriceps, hamstring, and gluteal muscle groups. Functional performance assays included prone hip extension repetitions to measure gluteus, paced curl-up performance and side plank endurance to measure abdominal muscles and seated quadriceps extension repetitions for measuring quadriceps strength. Subject reported body perception was documented. Outcome measures were performed at baseline, week 5 (pre-last treatment), and week 9 (4 weeks post last treatment). Subjects’ performance over time and comparisons between groups were analyzed. Results The treatment group demonstrated statistically significant gain in repetition-based and endurance-based performance measures compared with baseline and control subjects. Improvements were maintained through the 4-week follow-up. Treated subjects body self perception was improved. The procedure was well tolerated, with low discomfort and no reported adverse events. Conclusions Treatment with PlyoPulse technology was associated with measurable improvements in functional performance, enhanced body self perception and a favorable safety profile. The findings suggest that stimulation patterns incorporating a programmable synchronized multi muscles activation may better enhance coordinated neuromuscular recruitment consistent with exercise physiology.
Reference Key
openalex_W7204006215 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Kiya Movassaghi, Niloo Marashi, Shlomit Mann, Ruthie Amir
Journal Aesthetic surgery journal
Year 2026
DOI
10.1093/asj/sjag167
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.