V-26. A Novel Technique of SureForm–Based Intrathoracic Esophago-Gastric Anastomosis With Pleural Patch Reinforcement During Robotic-Assisted Minimally Invasive Esophagectomy

Clicks: 14
ID: 326190
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #448 of 453 articles by views in diseases of the esophagus : official journal of the international society for diseases of the esophagus

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 453 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Topic Esophageal Cancer: Surgical Treatment of Esophageal Cancer – technique Video Description This video demonstrates a standardized, fully robotic approach to SureForm-based gastric conduit preparation and a novel SureForm stapler–based intrathoracic esophago-gastric anastomosis with pleural patch reinforcement during robotic-assisted minimally invasive esophagectomy. The video begins with gastric conduit creation using the robotic SureForm stapler. Key steps highlighted include preservation of the right gastroepiploic arcade, uniform conduit width, precise stapler alignment, and avoidance of torsion to ensure optimal conduit perfusion. The advantages of robotic stapling, including controlled articulation, consistent staple formation, and surgeon autonomy, are emphasized. Following thoracic mobilization of the esophagus, a totally robotic intrathoracic esophago-gastric anastomosis is performed using the SureForm stapler. Under three-dimensional magnified visualization, precise enterotomies are created on the esophageal stump and gastric conduit. The stapler is used to construct the anastomosis and close the common channel in a controlled, stepwise manner, ensuring accurate tissue apposition and a tension-free anastomosis without reliance on bedside stapling or hand suturing. A novel aspect of this technique is pleural patch reinforcement, wherein mediastinal pleural flap is mobilized and used to buttress the anastomosis. This reinforcement aims to enhance anastomotic protection, potentially reducing the risk of leak and mediastinal contamination, while maintaining technical simplicity. The video concludes by summarizing key technical pearls, including conduit orientation, stapler positioning, perfusion assessment, and reproducibility of the technique. This standardized SureForm-based approach demonstrates a safe, efficient, and fully robotic strategy for gastric conduit preparation and intrathoracic esophago-gastric anastomosis during robotic-assisted minimally invasive esophagectomy.
Reference Key
openalex_W7203987035 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal diseases of the esophagus : official journal of the international society for diseases of the esophagus
Year 2026
DOI
10.1093/dote/doag077.426
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.