P1.188. Correlation Between ICG Fluorescence Angiography Kinetics and Tissue Oxygen Saturation Gradients During Gastric Conduit Perfusion Assessment

Clicks: 18
ID: 326030
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #268 of 453 articles by views in diseases of the esophagus : official journal of the international society for diseases of the esophagus

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 453 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Topic Esophageal Cancer: Surgical Treatment of Esophageal Cancer Background Poor gastric conduit perfusion is associated with post-esophagectomy anastomotic leak. Oxygen saturation imaging (OSI) can be used to demonstrate a snapshot assessment of perfusion as an alternative to fluorescent angiography. We hypothesized that fluorescence kinetics and oxygen saturation perfusion gradient (ΔStO₂) would provide similar gastric conduit information during esophagectomy. Methods Intraoperative perfusion assessment data was prospectively collected for patients undergoing esophagectomy at a single, high-volume, quaternary hospital. OSI data using a laparoscope (Fujifulm) were obtained at 4 distinct time points including baseline perfusion, ligation of short gastric arteries, ligation of the left gastric artery, and after gastric conduit preparation. Changes in perfusion during stepwise ligation were noted and final gastric conduit preparation was compared to the standard SPY © (Stryker) indocyanine green dye perfusion assessment, performed after conduit preparation. Changes in perfusion during stepwise ligation were noted and compared by t-test. SPY ingress slope and ingress peak fluorescence intensity were extracted from perfusion curves, while ΔStO₂ was defined as the difference in tissue oxygen saturation between the conduit base and tip. Continuous and categorical variables were summarized descriptively. Pearson correlation tested univariate relationships between SPY parameters and ΔStO₂, and linear regression assessed independent associations. Results A total of 23 patients were analyzed (mean age 62.9 ± 14.1 years, 74% male). Mean ΔStO₂ from conduit base to tip was –14.5 ± 12.2%, indicating a progressive decline in oxygen saturation distally. Mean SPY ingress slope was 21.4 ± 10.7 and ingress peak 181.7 ± 55.7. ΔStO₂ demonstrated no significant correlation with SPY ingress slope (r = 0.15, p = 0.48) or ingress peak (r = –0.01, p = 0.97). In multivariable linear regression, neither ingress slope (β = 0.56, p = 0.21) nor ingress peak (β = –0.09, p = 0.29) was independently associated with ΔStO₂ (R2 = 0.08). Conclusion SPY fluorescence ingress kinetics and oxygen saturation gradients represent distinct physiologic measures of gastric conduit perfusion. The absence of correlation between SPY and OSI parameters suggests that dye transit and hemoglobin oxygenation provide complementary, rather than overlapping, information regarding tissue viability. More data is necessary to determine if OSI can be used to predict the risk of leak.
Reference Key
openalex_W7203973927 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal diseases of the esophagus : official journal of the international society for diseases of the esophagus
Year 2026
DOI
10.1093/dote/doag077.336
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.