Stability-Indicating RP-HPLC Determination of Acetylsalicylic Acid, Dextromethorphan Hydrobromide, Phenylephrine Bitartrate, and Chlorpheniramine Maleate in an Effervescent Tablet Formulation

Clicks: 35
ID: 324164
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #312 of 376 articles by views in journal of aoac international

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 376 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
BACKGROUND: Multi-component effervescent tablets containing acetylsalicylic acid (ASA), dextromethorphan hydrobromide (DMH), phenylephrine bitartrate (PB), and chlorpheniramine maleate (CPM) pose analytical challenges due to their complex excipient composition and moisture sensitivity. Accurate quantification of these active pharmaceutical ingredients and their related degradation products or impurities is essential for product quality and stability evaluation. OBJECTIVE: To develop and validate a stability-indicating reversed-phase HPLC (RP-HPLC) method for the determination of ASA, DMH, PB, CPM in an effervescent tablet formulation, together with the monitoring of selected related impurities. METHODS: Chromatographic separation was achieved on an InertSustain C8 column (150 × 4.6 mm, 5 µm) using a phosphate buffer-methanol gradient containing sodium heptane sulfonate at pH 2.0, with dual-wavelength detection at 215 and 304 nm. The method was validated per ICH Q2(R2) for specificity, linearity, accuracy, precision, and solution stability. Forced degradation studies under acid, base, oxidative, photolytic, and thermal conditions confirmed stability-indicating capability. RESULTS: The method provided baseline resolution of all analytes within a single chromatographic program. Linearity (R² > 0.998 for APIs, > 0.993 for impurities), recoveries (98-102% for APIs, 90-110% for impurities), and precision (%RSD ≤ 2.0 for APIs, ≤ 5.0 for impurities) met acceptance criteria. CONCLUSION: The developed RP-HPLC method demonstrated reliable performance and can be applied for routine quality control and stability testing of the evaluated effervescent tablet formulation containing multiple active ingredients. HIGHLIGHTS: This method employs ion-pairing at pH 2.0 optimized for the effervescent matrix and dual-wavelength detection for the quantification of actives and selected impurities. Fully validated per ICH Q2(R2), it demonstrates a clear stability-indicating capability and suitability for QC and stability studies of the evaluated effervescent tablet formulation.
Reference Key
openalex_W7201837210 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal journal of aoac international
Year 2026
DOI
10.1093/jaoacint/qsag070
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.