SP 1.07 International Guideline Adherence in Elective Primary Umbilical Hernia Repair: CIRCULAR- a prospective cohort study (Collaborative International Research of Umbilical Hernia Repair)

Clicks: 18
ID: 323933
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #351 of 432 articles by views in the british journal of surgery

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 432 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Globally, >20 million hernia repairs are performed annually, with umbilical hernias accounting for up to 25%. Surgical repair of a primary umbilical hernia is guided by European Hernia Society and Americas Hernia Society recommendations. We aimed to report adherence to these guidelines. A prospective cohort study was performed (April-July 2025) across 21 countries (n=79 hospitals) (CIRCULAR). Adults aged ≥18 years undergoing elective repair of a primary umbilical hernia with defect size ≤4 cm were included. Guideline adherence components recorded were: for hernia defects <1cm, suture (non-absorbable/ slowly absorbable) or mesh were appropriate; hernia defects ≥1cm, mesh is recommended. When mesh was inserted adherence to mesh position (preperitoneal or retromuscular) and mesh overlap (≥5 cm for laparoscopic repairs; ≥3 cm for open) were reported. Differences between countries were assessed (chi-square testing). 1047 patients were included (48% of patients in age range 45-64; 67.9% male). For defects <1cm (15.3% of cases), suture repair was performed in 87.5% (appropriate suture used in 88.6%). For the 12.5% repaired with mesh, appropriate mesh position and overlap was achieved in 88.6%). For defects ≥1cm (84.7%), mesh repair was performed in 63% of cases with appropriate position in 60.1% and overlap in 38.5%. Overall adherence to guidelines was 27.8% and varied significantly between countries, ranging from 12.4% (UK) to 67.7 % (Germany) (χ² = 119.43, d.f. = 19 p < 0.001). Adherence to professional guidelines for primary umbilical hernia repair is low. CIRCULAR’s next analysis will determine whether this variation translates into meaningful differences in patient outcomes.
Reference Key
openalex_W7172490352 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal the british journal of surgery
Year 2026
DOI
10.1093/bjs/znag087.013
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.