CFD analysis on heat and flow characteristics of double helically coiled tube heat exchanger handling MWCNT/water nanofluids.

Clicks: 348
ID: 32386
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #103 of 235 articles by views in Heliyon

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 235 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Double helically coiled tube heat exchangers are used in different heat transfer utilization due to higher heat transfer capabilities and with their compactness. The double helically coiled tube heat exchanger increases the turbulence and enhances the maximum heat transfer rate than the straight tubes. In this investigation, the heat transfer and pressure drop of the double helically coiled heat exchanger handling MWCNT/water nanofluids have been analyzed by the computational software ANSYS 14.5 version. The computational analysis was carried out under the laminar flow condition in the Dean number range of 1300-2200. The design of new shell and double helically coiled tube heat exchanger was done by using standard designing procedure and 3D modeling was done in Cre-O 2.0 parametric. The Finite Element Analysis software ANSYS Workbench 14.5 was used to perform CFD analysis under the standard working condition. The MWCNT/water nanofluids at 0.2%, 0.4%, and 0.6% volume concentrations have been taken for this investigation. The major factors like volume concentrations of nanofluids and Dean Number are considered for predicting the heat transfer rate and pressure drop. The simulation data was compared with the experimental data. It is studied that the heat transfer rate and pressure drop increase with increasing volume concentrations of MWCNT/water nanofluids. It is found that the Nusselt number of 0.6% MWCNT/water nanofluids is 30% higher than water at the Dean number value of 1400 and Pressure drop is 11% higher than water at the Dean number value of 2200. It is found that the simulation data hold good agreement with the experimental data. The common deviation between the Nusselt number and pressure dropof CFD data and the Nusselt number and pressure drop of experimental data are found to be 7.2% and 8.5% respectively.
Reference Key
mukesh-kumar2019cfdheliyon Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Mukesh Kumar, P C;Chandrasekar, M;
Journal Heliyon
Year 2019
DOI
10.1016/j.heliyon.2019.e02030
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.