Hemolysis and Renal Effects Across Pulsed Field Ablation Systems in Atrial Fibrillation
Clicks: 15
ID: 323008
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
4.2
/100
15 views
0 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #9 of 79 articles by views in EP Europace
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
INTRODUCTION: Pulsed field ablation (PFA) is a non-thermal energy modality for ablation of atrial fibrillation (AF). Although PFA has demonstrated an excellent overall safety profile, increasing evidence suggests an association with intravascular hemolysis, and acute kidney injury (AKI). However, the extent of hemolysis across different PFA catheters remains poorly characterized and warrants further investigation. METHODS: We prospectively enrolled 239 patients undergoing AF ablation using the pentaspline (n = 107), balloon-in-basket (n = 71), or lattice-tip (n = 61) catheter. Laboratory markers of hemolysis, myocardial injury, renal function and haemoglobin were collected pre- and 24 h post-procedure. RESULTS: Significant haptoglobin depletion was observed exclusively with pentaspline, [pre 99.8 mg/dL (70.2-122) vs. post 55.7 mg/dL (23.2-91.8); p < 0.001] Reductions with the lattice-tip (p = 0.074) and the balloon-in-basket (p = 0.201) catheter did not reach statistical significance. AKI was only observed with the pentaspline catheter (pentaspline: 4.9%; balloon-in-basket: 0.0%; lattice tip: 0.0%; p = 0.020).Myocardial markers increased across all groups, but significantly higher in pentaspline and balloon-in-basket (p = n.s.) vs lattice-tip (p < 0.001 vs pentaspline, p < 0.001 vs ballon in basket). CONCLUSIONS: In this large cohort, contemporary PFA systems appear safe but catheter design influences the extent of hemolysis, AKI, and myocardial injury. The pentaspline catheter was associated with the greatest hemolytic effect and higher transient AKI, without clinically relevant reductions in hemoglobin or persistent renal impairment. Higher levels of myocardial injury in the pentaspline and balloon-in-basket groups correspond to the larger lesion footprints of these devices.Word counting abstract: 234.
| Reference Key |
openalex_W7171793518
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Matteo Rocchetti, David Schaack, A Marrese, Andrea Urbani, Joseph Kheir, Soroosh Najafi, Melanie Gunawardene, Julia Alexandra Marx, Julia Lurz, Boris Schmidt, K. R. Julian Chun, Lukas Urbanek |
| Journal | EP Europace |
| Year | 2026 |
| DOI |
10.1093/europace/euag190
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.