Dose-Response Associations Between Sleep Duration and Health Outcomes in Adults: Comparison Between Self-Reported and Device-Based Measures

Clicks: 2
ID: 321157
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #84 of 186 articles by views in Sleep & breathing = Schlaf & Atmung

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 186 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
STUDY OBJECTIVES: This study aimed to: (i) assess whether associations between sleep duration and health outcomes differ by measurement method (self-report vs. actigraphy); and (ii) compare dose-response curves to evaluate whether sleep duration recommendations should vary based on the method of assessment. METHODS: We conducted a prospective cohort study using data from UK Biobank participants aged 40-69 years who wore wrist-worn accelerometers for 7 days and self-reported their daily sleep duration. Outcome measures included all-cause mortality, incident cardiovascular disease (CVD), type 2 diabetes, dementia, and depression. Dose-response associations between sleep duration-measured using device-based metrics (total sleep time and sleep period time) as well as self-report-and these outcomes were examined, adjusting for multiple covariates. RESULTS: We analyzed data from 69,153 adults for cardiovascular disease (CVD) and up to 76,811 adults for mortality, with an average follow-up of 8.0 (SD: 0.9) years. Across all sleep measurement methods, adjusted dose-response curves showed a similar inverse J-shaped pattern (particularly for device-based measures), and a U-shaped association for incident depression. Associations were stronger for sleep period time than for the other sleep metrics. For example, a sleep period time of 7 hours was associated with a 30% lower risk of mortality relative to the 5-hour reference value (HR: 0.70; 95% CI: 0.61-0.79). In comparison, a total sleep time and a self-reported sleep duration of 7 hours were associated with 17% (HR: 0.83; 95% CI: 0.78-0.89) and 14% (HR: 0.86; 95% CI: 0.74-1.00) lower mortality risk relative to the 5-hour reference value, respectively. The lowest estimated risk across outcomes occurred at approximately 7.2 hours for self-reported sleep, 7.7 hours for sleep period time, and between 6.8 and 9.3 hours for total sleep time. CONCLUSIONS: Both self-reported and device-measured sleep durations demonstrated broadly similar dose-response relationships with health outcomes, although associations were substantially stronger for device-measured sleep period time. These findings support existing evidence that 7-9 hours of sleep per night is optimal for adults, regardless of how sleep is measured, and suggest that sleep period time may be more relevant than total sleep time for future device-based recommendations.
Reference Key
openalex_W7168358426 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Jean-Philippe Chaput, Raaj Kishore Biswas, Matthew Ahmadi, Peter A Cistulli, Wenxin Bian, Emmanuel Stamatakis
Journal Sleep & breathing = Schlaf & Atmung
Year 2026
DOI
10.1093/sleep/zsag193
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.