Beyond Device Downloads: Residual Sleep Apnea and Hypoxemia Missed by Flow-Based CPAP Monitoring
Clicks: 2
ID: 320766
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
0.3
/100
2 views
0 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #79 of 186 articles by views in Sleep & breathing = Schlaf & Atmung
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 186 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
STUDY OBJECTIVES: Positive Airway Pressure (PAP) therapy download reports are the currentobjective data standard for assessing sleep apnea treatment success, providing information onusage, leak, and residual apnea-hypopnea index (AHI). However, follow-up parallel testing can offer added value in measuring sleep and respiratory health in patients receiving PAP therapy. This study compares residual PAP-derived AHI (AHIFLOW) with cardiopulmonary coupling (CPC)-derived AHI3% (AHICPC). We specifically examined patients for whom PAP therapy would be considered effective, but follow-up testing indicated potentially significant residual disease. METHODS: As part of standard clinical care, patients in our telemedicine sleep program undergo longitudinal home sleep testing using CPC through the SleepImage system. We retrospectively analyzed remote physiological monitoring data from ResMed PAP devices and CPC-based sleep testing on nights with concomitant data. RESULTS: A total of 465 patients met the inclusion criteria, contributing 24,939 nights of matched PAP and CPC data. Mean AHIFLOW was 2.4 events/hour, while mean AHICPC was 12.1 events/hour. Among nights with AHIFLOW <5 events/hour, 85% of nights had AHICPC ≥5 events/hour, 47.7% had AHICPC ≥10 events/hour; 28.3% had ≥5 minutes with SpO2 <90%, and 10.6% had ≥5 minutes with SpO2 <88%. CONCLUSIONS: PAP download reports are useful for assessing usage and leak, but mayunderestimate residual respiratory burden. Besides periods of non-use, device-based flow-based metrics alone can miss clinically meaningful residual disease, including hypoxic events during REM sleep. Reliance on PAP-derived AHI as the sole efficacy metric risks overlooking persistent disease.
| Reference Key |
openalex_W7168105653
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Savit Raj Malhotra, Do Qb, Stacey Gunn, Sahil Chopra, Kirstin Knobbe Lloyd, Robert J. Thomas |
| Journal | Sleep & breathing = Schlaf & Atmung |
| Year | 2026 |
| DOI |
10.1093/sleep/zsag189
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.