TDLAS-Based Antimicrobial Susceptibility Testing Using Microbial CO2 Evolution and Validation in Gram-Positive and Gram-Negative Bacteria

Clicks: 46
ID: 319743
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #110 of 230 articles by views in Journal of applied microbiology

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 230 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Abstract Introduction Rapid and accurate antimicrobial susceptibility testing (AST) is pivotal for guiding clinical therapy and curbing antimicrobial resistance (AMR). Traditional AST methods despite being the gold standard, lack real-time growth kinetic information and often involve invasive or cumbersome procedures. This study aims to develop a universal, non-invasive AST method based on Tunable Diode Laser Absorption Spectroscopy (TDLAS). Methods Through the monitoring of microbial CO2 evolution in the headspace of sealed culture bottles, established a calibration curve relating threshold time (TT) to total viable count (TVC) and constructed a dose-response model to quantitatively determine the minimum inhibitory concentration (MIC). Results Validation using the Staphylococcus sciuri standard strain demonstrated that the MIC of ampicillin (0.16–0.18 mg∙mL−1) determined by this method was highly concordant with the CLSI M07 standard broth microdilution method. Four independent replicates exhibited excellent stability, with a coefficient of variation (CV) of only 2.75%. The method was further successfully extended to clinical isolates, validating its applicability across Gram-positive bacteria (Staphylococcus aureus) and Gram-negative bacteria (Escherichia coli, Enterobacter cloacae). Different from traditional methods, the continuous monitoring capability of this system visually captures detailed growth dynamics under antibiotic stress (such as growth delays and partial inhibition) providing a richer dimension of information for resistance evaluation. Conclusion As a universal, non-invasive, and low-cost approach, this AST method provides MIC values consistent with standard protocols while providing richer detailed growth dynamics information than traditional methods. Consequently, this method shows significant potential for deployment in clinical on-site settings and resource-limited environments.
Reference Key
openalex_W7167511448 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal Journal of applied microbiology
Year 2026
DOI
10.1093/jambio/lxag164
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.