Ultrasound in Gluteal Fat Grafting: Safety Tool, Standard of Care, or Emerging Evidence?: A Scoping Review

Clicks: 2
ID: 318616
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #54 of 72 articles by views in Aesthetic surgery journal

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Gluteal fat grafting is associated with rare but potentially fatal complications, particularly fat embolism related to inadvertent intramuscular injection. Current safety recommendations emphasize strict subcutaneous fat placement. Intraoperative ultrasound has been proposed as a tool to enhance procedural safety; however, the extent and quality of supporting evidence remains unclear. A scoping review was conducted according to PRISMA-ScR and Joanna Briggs Institute methodology. Six electronic databases were searched from the earliest available records through March 2025. Studies including adult patients undergoing ultrasound-guided gluteal fat grafting were eligible. Nine studies published between 2018 and 2025 met inclusion criteria. Evidence consisted predominantly of observational case series and one systematic review with meta-analysis; no randomized or high-quality comparative studies were identified. Ultrasound was primarily used to guide cannula positioning and confirm subcutaneous fat injection in real time. Verification of the injection plane relied mainly on intraoperative visualization rather than standardized imaging-based confirmation. No cases of fat embolism or procedure-related mortality were reported. Additional procedural benefits were described but were largely qualitative and infrequently assessed using comparative outcome measures. Intraoperative ultrasound appears to be a useful safety adjunct in gluteal fat grafting; however, current evidence is limited and primarily non-comparative. Further comparative studies are required to establish its clinical benefit.
Reference Key
openalex_W7165749760 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Ximena Camila Vázquez-Guerra, Luis Adrian Alvarez-Lozada, Jojhan Joel Altuzar-Abadía, Luis Carlos Lozano-Carrillo, Cynthia M. González-Cantú, Neri Alejandro Alvarez-Villalobos, Yanko Castro-Góvea
Journal Aesthetic surgery journal
Year 2026
DOI
10.1093/asj/sjag120
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.