Prognostic Impact of Biplane Vena Contracta Width in Patients with Atrial Functional Mitral Regurgitation

Clicks: 19
ID: 318339
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #81 of 158 articles by views in European Heart Journal - Cardiovascular Imaging

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 158 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
BACKGROUND: The vena contracta width (VCW) in parasternal long axis view (PLAX-VCW) and effective regurgitant orifice area (EROA) may underestimate the mitral regurgitation (MR) severity because of the elliptical-shaped effective orifice in atrial functional MR (AFMR). We aimed to assess the association between the vena contracta width by biplane method (Bi-VCW) and clinical outcomes in patients with AFMR and to compare the discriminative ability of Bi- VCW with those of other quantitative/semiquantitative metrics. METHODS: This was a substudy of a multicentre registry of moderate or severe AFMR. The Bi-VCW was evaluated as the average of the apical two-chamber and four-chamber views. The primary outcome was a composite of all-cause mortality, heart failure hospitalization, and mitral valve interventions. RESULTS: Among 423 studied patients, the Bi-VCW was higher than PLAX-VCW (8.1 ± 2.4 vs. 4.8 ± 1.9 mm, p < 0.001); the guideline-recommended threshold of Bi-VCW of >8.0 mm stratified 48% as severe MR. The Bi-VCW showed the highest discriminatory performance of the primary outcome (area under the time-dependent receiver operating characteristic curve of 0.76) compared with the PLAX-VCW and EROA and revealed an optimal threshold of 7.9 mm (sensitivity, 76%; specificity, 65%). In the multivariable Cox proportional hazards model, Bi- VCW >8.0 mm was independently associated with a higher risk of the primary outcome (adjusted hazard ratio=2.97, 95% confidence interval: 2.04-4.32, p < 0.001). CONCLUSIONS: The Bi-VCW was independently associated with poorer outcomes in patients with AFMR and demonstrated superiority over the guideline-recommended parameters. It could serve as an independent and first surrogate for risk stratification in patients with AFMR.
Reference Key
openalex_W7165544034 Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal European Heart Journal - Cardiovascular Imaging
Year 2026
DOI
10.1093/ehjci/jeag157
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.