No Incremental Benefit of Coil-Assisted Over Ethanol Embolization in Unilateral Primary Aldosteronism
Clicks: 1
ID: 317894
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
0.0
/100
1 views
0 readers
AI Quality Assessment
Not analyzed
Readership in this journal
Ranked #51 of 62 articles by views in American Journal of Hypertension
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
BACKGROUND: Selective adrenal arterial embolization (SAAE) is an alternative treatment for unilateral primary aldosteronism (PA), but its overall success remains variable. We evaluated whether coil-assisted ethanol embolization (Coil-E) improves outcomes compared with ethanol embolization alone in patients undergoing single-vessel SAAE. METHODS: In this retrospective study, patients with unilateral PA who underwent single-vessel SAAE between 2020 and 2021 were categorized into Coil-E and ethanol groups. The primary endpoint was clinical success at 12 months defined according to the Primary Aldosteronism Surgical Outcome (PASO) criteria. Secondary endpoints included biochemical success, changes in 24-hour ambulatory blood pressure (BP), and safety outcomes. Propensity score-based analyses were performed. RESULTS: Eighty-two patients were included (23 Coil-E, 59 ethanol). At 12 months, complete clinical success occurred in 17.4% vs. 20.3%, partial success in 47.8% vs. 35.6%, and absent success in 34.8% vs. 44.1% (Coil-E vs. ethanol; all P > 0.05). Complete biochemical success occurred in 39.1% vs. 55.9%, whereas absent biochemical success occurred in 34.8% vs. 28.8%. Mean 24-hour systolic/diastolic BP decreased by 21.6/10.1 mmHg in the Coil-E group and 20.5/9.7 mmHg in the ethanol group, with no significant between-group differences. Serum potassium and aldosterone improved in both groups without deterioration in renal function or cortisol levels. No major procedure-related complications occurred. Findings were consistent across adjusted analyses. CONCLUSION: Among patients with unilateral PA undergoing single-vessel SAAE, Coil-E was not associated with improved PASO-defined clinical or biochemical success compared with ethanol embolization alone.
| Reference Key |
openalex_W7165202395
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Zhi-Qiang Ma, Ning‐Peng Liang, Hong-liang XIONG, Jiao Yang, Zi‐Xin Lin, Yi-Fei Dong |
| Journal | American Journal of Hypertension |
| Year | 2026 |
| DOI |
10.1093/ajh/hpag061
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.