Performance Evaluation of a Commercial LC-HRMS Platform for Untargeted Whole Blood Analysis: Comparison with Immunoassay and LRMS Urine Screening and Targeted LC-MS/MS (MRM) Whole Blood Quantification
Clicks: 1
ID: 317560
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
0.0
/100
1 views
0 readers
AI Quality Assessment
Not analyzed
Readership in this journal
Ranked #45 of 48 articles by views in journal of analytical toxicology
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Abstract In forensic toxicology (FT), drug of abuse (DoA) screening is essential yet challenging. This study presents a vendor-based, high-resolution (HR) LC-MS/MS blood screening method implemented without in‑house optimization, in comparison to immunoassay-based and low-resolution (LR) urine screening approaches simultaneous to (semi)quantification. The HR-method allows detection of more than 3000 analytes, including DoAs, drugs, and suspected new psychoactive substances (NPS). Following protein precipitation, analytes qualitatively identified in 500 authentic whole-blood samples using the HR-method were qualitatively compared with results from immunoassay and LR urine screening. Additionally, 82 common DoAs and drugs were (semi)quantitatively validated according to ANSI and GTFCh guidelines, and quantitative performance was assessed against a fully-validated targeted LC-MS/MS method (MRM mode). In total, the HR-method detected 819 (83%) of the 994 analytes identified by LR urine screening. Substances not captured by the HR approach typically showed concentrations below the identification limit and/or were of negligible relevance in FT. The HR blood screening detected 66% of all cases positive for THC and/or its metabolites, whereas the LR urine screening failed to detect these compounds entirely. Incorporation of the HighResNPS® database enabled the tentative identification of 14 NPS. Seventy-four (90%) of the 82 DoAs demonstrated accuracy within ±30%, precision (CV) ≤30%, and quantitative results of 100 authentic cases were consistent with those from the targeted LC-MS/MS method which is generally considered the gold standard for quantification. Overall, the HR blood screening can replace LR urine screening enabling simultaneous detection of DoAs, their metabolites, and NPS. The (semi)quantitative validation of 74 drugs and the quantitative comparison confirmed the method’s reliability in distinguishing between subtherapeutic, therapeutic, and toxic concentrations without the need for drug class-specific optimization, thereby saving time, effort, and costs. This untargeted approach combines screening with (semi)quantification while supporting routine workflows, research applications, and retrospective analysis of new emerging substances.
| Reference Key |
openalex_W7164926146
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Annina Bovens, Lana Brockbals, Thomas Kræmer, Andrea E. Steuer |
| Journal | journal of analytical toxicology |
| Year | 2026 |
| DOI |
10.1093/jat/bkag050
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.