Achieving a more accurate method of standard addition (MSA) through mathematical improvements
Clicks: 1
ID: 317135
2026
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
0.0
/100
1 views
0 readers
AI Quality Assessment
Not analyzed
Readership in this journal
Ranked #32 of 48 articles by views in journal of analytical toxicology
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Abstract The method of standard addition (MSA) has recently benefited from a popularity boost. In this approach, aliquots from a sample with an unknown analyte concentration are spiked with increasing analyte concentration. When plotting the measured signals against the spiked concentrations, the absolute value of the x-axis intercept is the unknown’s concentration. Unfortunately, guidance on the best practices for performing MSA is extremely slim. In this paper, we rely on literature, mathematical theory, and in silico simulations to build a framework for optimal accuracy when implementing the MSA approach. Our recommendations are as follows. 1) The highest upspike concentration should be as high as possible without saturating the detector; at least 5 times the estimated unknown concentration is a good rule of thumb. 2) Adding measurement replicates should be favored over adding new upspike concentrations. 3) Upspikes towards the low end of the dynamic range should be favored, insofar as their signal is differentiable from the unknown. 4) To simplify calculations, coordinate swapping should be performed; i.e., signal measurements (e.g., area, area ratio) are recorded as the x values and spiked concentrations as the y values. 5) In performing the least squares regression, weight is set to 1/variance if three or more replicates are available, otherwise, to 1/(signal)2. 6) If the confidence interval of the quadratic (b2) parameter includes zero, then a linear model should be used for the regression. Otherwise, a quadratic model should be used. 7) Measurement uncertainty should be calculated using uncertainty contributors uCRM (uncertainty contributed by the certified reference material, as stated on its certificate of analysis) and uMSA (uncertainty contributed by the MSA procedure, which is the uncertainty of the y-intercept, ub0, when using a coordinate-flipped framework).
| Reference Key |
openalex_W7164556870
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Brigitte Desharnais, Jocelyn V. Abonamah, Szabolcs Sofalvi, Pascal Mireault |
| Journal | journal of analytical toxicology |
| Year | 2026 |
| DOI |
10.1093/jat/bkag047
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.